Replacement instructions - Gantry c able and hose carrier SIPLACE HS / S / F 01/2007 Edition 183 : Insert the free end of the cable and ho se carr ier (ribbon cable s and compressed air hoses) into the threading ai d (it…

100%1 / 198
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
182
: Use suitable tools to fix the cable and hose carrier in the cable and hose carrier mount and use
a cable tie to fix it to the power chain.
2
2
2
2
2
2
2
2
2
Cable ties
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
183
: Insert the free end of the cable and hose carrier (ribbon cables and compressed air hoses) into
the threading aid (item no. 00331124-01).
: Pull the flexible tubing over the cables and hoses.
2
: Add the two UMHW cable protective films to the cable and hose carrier as follows:
- one film between air hoses and ribbon cables,
- one film on the topmost ribbon cable.
Taper the ends of the film slightly so that it does not catch in the flexible tubing when you intro-
duce it.
2
Protective hose
Threading aid
Ribbon cable
Hose tape
Cable protective
films
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
184
: Place the cable and hose carrier in the cable and hose carrier mount so that the two added flat
cables and the Expando flexible tubing end flush with the end of the cable and hose carrier
mount.
2
All machines 2
: Make sure that the topmost ribbon cable is no more than 185 mm from the guide plate shown
in the picture. Tighten the cables slightly, if necessary.