00193161-01 - 第67页

Manual S-20/S-23 HM/S-25 HM/F4/F5 HM /HS-50 Placement of 0402 components 03/2001 edition 67 8.3.2 Parameters for ‘ LEAD ’ measuring mode Å From the ‘ Measur ing Mo de ’ menu (see Fi g. 8 - 5 on page 64 ), clic k on the ‘…

100%1 / 76
Placement of 0402 components Manual S-20/S-23 HM/S-25 HM/F4/F5 HM/HS-50
03/2001 edition
66
Å Click on the Integration Settings button. The following options must be checked in the Size
Measuring Mode, Integration Settings window:
Integration direction in the X direction
Resolution in meas. direction very high (every pixel)
Resolution in direction of integration very high (every pixel)
Fig. 8 - 7 Size measuring mode: Integration settings
Manual S-20/S-23 HM/S-25 HM/F4/F5 HM/HS-50 Placement of 0402 components
03/2001 edition
67
8.3.2 Parameters for LEAD measuring mode
Å From the Measuring Mode menu (see Fig. 8 - 5 on page 64), click on the Set …’ button for
Lead. The following options must be checked in the Lead Measuring Mode window:
Measur: Tip measurement via outer tips
Window: Separately for each pin
Fig. 8 - 8 Setting Lead measuring mode
Placement of 0402 components Manual S-20/S-23 HM/S-25 HM/F4/F5 HM/HS-50
03/2001 edition
68
8.3.3 Checking the hex values
Å From the Measuring Mode menu (see Fig. 8 - 5 on page 64), click on the Hex entries ...
button.
ATTENTION: 8
Only people with sufficient technical knowledge should change the parameters shown in Fig.
8 - 9. 8
Only the Size and Lead check boxes must be checked in the Measuring Mode 2 menu. The
parameters shown in Fig. 8 - 9
must be entered. 8
Fig. 8 - 9 Measuring Mode 2 Default setting