CYCLONE UNDER STENCIL CLEANER MODULE REPLACEMENT PROCEDURES 26.14 Technical Reference Manual Chapter Issue 11, Feb 18 chamber to the oscillating bracket. 10. Remove the vacuum chamber from the cleaner whilst disconnectin…

CYCLONE UNDER STENCIL CLEANER MODULE
REPLACEMENT PROCEDURES
Chapter Issue 11, Feb 18 Technical Reference Manual 26.13
To change the cyclone cleaner to a different fabric size, carry out the following:
1. Select Open Cover Commands.
2. Select Unload Screen.
3. Open the front printhead cover.
4. Remove the stencil from the machine.
5. Power down the machine.
6. Remove the fabric cassette from the cleaner tray.
7. Locate the solvent tube that connects the vacuum chamber to the in-line
connector.
8. Disconnect the solvent tube from the left hand side of the in-line connector.
9. Using a 4mm Allen key, remove the three screws that secure the vacuum
Vacuum Chamber
Solvent Pump
In-Line Connector
Solvent Tube
View on Right Hand Side of Cyclone Cleaner

CYCLONE UNDER STENCIL CLEANER MODULE
REPLACEMENT PROCEDURES
26.14 Technical Reference Manual Chapter Issue 11, Feb 18
chamber to the oscillating bracket.
10. Remove the vacuum chamber from the cleaner whilst disconnecting the
vacuum hose.
11. Using a 4mm Allen key, loosen the fabric feed motor securing screw.
12. Set the motor to the correct position using the graphic in Step 11 and the
following table:
13. Tighten the fabric feed motor securing screw.
Size Position
300mm 300mm marker aligned to the left face of the motor support plate
400mm 400mm marker aligned to the left face of the motor support plate
515mm Left edge of the motor aligned to the left face of the motor support plate
Vacuum Chamber Securing ScrewsVacuum Hose
Connection
Oscillating Bracket Vacuum Chamber
Plan View on Cyclone Cleaner

CYCLONE UNDER STENCIL CLEANER MODULE
REPLACEMENT PROCEDURES
Chapter Issue 11, Feb 18 Technical Reference Manual 26.15
14. Place the appropriate sized vacuum chamber on the oscillating bracket and
connect the vacuum hose.
15. Using the graphic below, align the vacuum chamber to the appropriate set
of holes.
16. Refit the three securing screws.
17. Connect the solvent tube from the vacuum chamber to the in-line connector.
18. Fit the correct size fabric cassette with a fabric roll fitted.
19. Close the printhead cover.
20. Power up the machine and press the System button when prompted.
21. Select Open Cover Commands.
22. Open the front printhead cover.
23. Select Prime Solvent.
24. When prompted, press the two control buttons simultaneously ensuring that
the solvent is wetting the fabric above the vacuum chamber.
25. If fabric counting is disabled, go to Step 29.
26. Select Change Paper.
27. Ensure the fabric length parameter matches that stated on the fabric roll
wrapper.
28. Select Continue.
29. Select Prime Paper.
30. When prompted, press the two control buttons simultaneously ensuring that
the fabric feeds correctly and any slack is taken up.
31. Refit the stencil.
32. Close the front printhead cover.
33. Press the System button.
34. Select Load Screen.
35. Select Back.
Plan View on Cyclone Cleaner
515mm 400mm 300mm 300mm 400mm 515mm
Oscillating Bracket