CYCLONE UNDER STENCIL CLEANER MODULE CALIBRATIONS 26.20 Technical Reference Manual Chapter Issue 11, Feb 18

CYCLONE UNDER STENCIL CLEANER MODULE
CALIBRATIONS
Chapter Issue 11, Feb 18 Technical Reference Manual 26.19
7. Replace the empty 5 litre container with a 5 litre container full of the solvent
to be used.
8. Select Set Solv Full and confirm by selecting Yes.
9. Select Exit.
10. Select Exit.
11. Select Back.
Fabric If fabric counting is enabled, the software needs to know the fabric roll length
when first fitted to the under stencil cleaner.
NOTE
The length of the fabric roll is printed on the fabric roll wrapping.
To calibrate the software carry out the following procedure:
1. Select Open Cover Commands.
NOTE
If the stencil image is centre justified, the stencil may need to be removed
to gain access to the Cyclone under screen cleaner.
2. Open the front printhead cover.
3. Change the fabric cassette as detailed in the consumable replenishment.
4. Select Change Paper.
5. Ensure the fabric length parameter matches that stated on the fabric roll
wrapper.
6. Select Continue.
7. Select Prime Paper.
8. When prompted, press the two control buttons simultaneously ensuring that
the fabric feeds correctly and any slack is taken up.
9. Close the front printhead cover.
10. Press the System button.
11. Select Back.
12. Select Back.

CYCLONE UNDER STENCIL CLEANER MODULE
CALIBRATIONS
26.20 Technical Reference Manual Chapter Issue 11, Feb 18

RISING TABLE MODULE - STYLE 1
OVERVIEW
Chapter Issue 9, Aug 14 Technical Reference Manual 27.1
CHAPTER 27 RISING TABLE MODULE - STYLE 1
OVERVIEW
NOTE
For details on the Remote Board Stop and sensors refer to the Board Stop
Chapter.
Item Description Item Description
1 Rail to Table Height Adjuster (in 4 positions) 5 Rising Table Motor with Integral Electromagnetic Brake
2 Rising Table Leadscrew 6 Rising Table Drive Belt
3 Home Vane 7 Linear Bearing Guide (in 2 positions)
4 Home Sensor 8 Manual Tooling Plate
View on Rear Right of Rising Table
NOTE
The rising table home position is
lower with Modular Transport Rail
system therefore, the home vane
has a smaller vane.
1
8
2
3
4
7
6
5