192277 - Micron Technical Reference Volume 3 - 第181页
AIR IONIZER MODULE OVERVIEW Chapter Issue 5, Aug 14 Technical Reference Manual 31.1 CHAPTER 31 AIR IONIZER MODULE OVER VI EW Item Descrip tion Item Description 1 Air Inlet 4 Air Regulator 2 Air Ionizer Bracket (in 2 posi…

PASTE ROLL HEIGHT MONITOR
REPLACEMENT PROCEDURES
30.12 Technical Reference Manual Chapter Issue 3, Aug 14
7. On completion, power up and initialize the machine and carry out Squeegee
Reference Height setting.
Removal Carry out the following procedure to remove the Roll Height Monitoring from the
machine:
1. Ensure the machine is powered down.
2. Release the front squeegee thumbscrews and remove the front squeegee.
3. Disconnect the electrical connector 9PL60 from 9SK60.
4. Using a 4mm Allen key, loosen the three Roll Height Monitor assembly
securing screws and remove the monitor assembly from the machine.
5. Fit the front squeegee ‘I’ bar and secure with the three cap headed bolts and
refit the front squeegee to the front squeegee ‘I’ bar.
6. On completion, power up and initialize the machine and carry out Squeegee
Reference Height setting (see Squeegee Module, Infinity Technical Refer-
ence Manual for details).

AIR IONIZER MODULE
OVERVIEW
Chapter Issue 5, Aug 14 Technical Reference Manual 31.1
CHAPTER 31 AIR IONIZER MODULE
OVERVIEW
Item Description Item Description
1 Air Inlet 4 Air Regulator
2 Air Ionizer Bracket (in 2 positions) 5 +24VSW Power In
3 Air Ionizer 6 Air Ionizer Electrodes
1
5
6
2
3
4

AIR IONIZER MODULE
OVERVIEW
31.2 Technical Reference Manual Chapter Issue 5, Aug 14
The air ionizer reduces the amount of static electricity to +100V, making it safe
for most static sensitive components which enter the machine.
Air is supplied to the input of the ionizing unit. An array of electrodes, mounted
on the base of the unit, ionizes the air supply. The electrodes consist of a pair
of corona discharge needles which receive a positive and negative dc waveform
at 7kV, 20Hz: producing an ionizing potential of+100V.
The electrodes are housed in a cartridge, which makes them easy to fit and
remove from their housing. Three types are available:
• Tungsten: ion balance +30V
• Silicon: ion balance +30V (used in environments sensitive to metal con-
tamination)
• Stainless Steel: ion balance +100V
Currently, ASM supply the stainless steel electrode units.
The air supply, set to 2 bar, is routed over the electrodes, ensuring a wide
dispersal of ionized air; this functionality increases the speed of static reduction.
Modes of
Operation
There are three modes of operation:
• Sensing DC Mode
• Pulse DC Mode
• DC Mode
Pulse DC Mode Currently, ASM utilise the Pulse DC Mode. The ionizer alternately emits positive
and negative ions (pulsed dc) to dissipate any spatial static charge, which may
be present in the working area.
If the ion balance voltage exceeds +100V, this may be due to needle contami-
nation; the ionizer outputs a maintenance signal. This action causes a needle
check indicator to initially pulse on and off, signalling that there may be needle
contamination. After a period of time, the indicator stays on signalling that
maintenance is required. Usually this consists of cleaning the electrode pairs.
Power Supply The air ionizer derives its power from the 24V switched supply (M37) and is
disabled when the printhead cover is open or the E Stop is pressed.
NOTE
When the air ionizer is electrically disabled, air pressure continues to flow
through the electrodes.