AIR IONIZER MODULE ADJUSTMENTS AND SETTINGS Chapter Issue 5, Aug 14 Technical Reference Manual 31.5 Air Regulator The air regulator sets the air pressure to the air ionizer and must be set to 0.20MPa ( 2.0 bar ). T o adj…

AIR IONIZER MODULE
ADJUSTMENTS AND SETTINGS
31.4 Technical Reference Manual Chapter Issue 5, Aug 14
ADJUSTMENTS AND SETTINGS
Pulse DC Mode
Settings
The air ionizer settings are factory set. Use the following graphic and table to
ensure that the switches on the control panel of the air ionizer are set correctly.
NOTE
Setting this trimmer correctly requires the separate use of measuring equipment
to verify the ion balance.
No. Description Function
1 Zero Adjust Trimmer Used to adjust the ion balance when the auto
balance sensor is not in use. This is factory set and
should not need adjustment. *See Note
2 Frequency Select Rotary Switch Position 0 = 1Hz
Position 1 = 3Hz
Position 2 = 5Hz
Position 4 = 10Hz
Position 5 = 20Hz (Factory recommended setting)
Position 6 = 30Hz
Position 7 = 60Hz
Position 8 = N/A
Position 9 = N/A
3 Level Select Switch Electrode stain level is detected. In the manual
mode, only positions H, M & L are functional.
Preset to position M. See stain detection for
details.
4 Alarm NDL Check Illuminates (Red) when electrode stain is detected.
Blinks during detection.
5SNSR N/A
6 HV Illuminates (Red) when an abnormal current flows
through an electrode needle.
7 ION + Illuminates (Orange) when positive ions are being
generated.
8 ION OK N/A
9 ION - Illuminates (Blue) when negative ions are being
generated.
10 Power SNSR N/A
11 Power Main Illuminates (Green) when power is present. Blinks
if power is interrupted.
H
L
M
H
M
L
MANUAL
AUTO
MANUAL
LEVEL
Zero
Adjust
NDL
CHECK
+
SNSRSNSR
OK
MAINHV
-
ALARM
ION POWER
2
3
7
8
FREQ SELECTFREQ SELECT
6
7
8
5
4
3
6
7
5
4
3
1
2
3
4
5
6
7
8
9
10
11

AIR IONIZER MODULE
ADJUSTMENTS AND SETTINGS
Chapter Issue 5, Aug 14 Technical Reference Manual 31.5
Air Regulator The air regulator sets the air pressure to the air ionizer and must be set to
0.20MPa (2.0 bar). To adjust the air pressure, use the following procedure:
1. Pull the regulator control valve upwards to unlock it.
2. Turning the regulator control valve clockwise to increase the pressure or
anti-clockwise to decrease the pressure, set the pressure to 0.20MPa (2.0
bar).
3. With the pressure set, push the regulator control valve downwards to lock it.
Regulator Control Valve
Air Out to Air Ionizer
Pressure Gauge Air In
View on Air Regulator

AIR IONIZER MODULE
REPLACEMENT PROCEDURES
31.6 Technical Reference Manual Chapter Issue 5, Aug 14
REPLACEMENT PROCEDURES
WARNING
COMPRESSED AIR. COMPRESSED AIR SHOULD NEVER IMPINGE UPON THE
BODY. PORTS, PIPES, ETC MUST NEVER BE BLOCKED BY HAND. BEFORE
CONNECTING OR DISCONNECTING ANY PNEUMATIC COMPONENTS, ENSURE
THE COMPRESSED AIR SUPPLY HAS BEEN DISSIPATED AND DISCONNECTED
FROM THE MACHINE.
WARNING
LETHAL VOLTAGE. DANGEROUS VOLTAGES EXIST IN THIS EQUIPMENT.
ENSURE ALL ELECTRONIC COVERS AND MAIN MACHINE COVERS ARE FITTED
BEFORE OPERATING THIS EQUIPMENT.
Stain Detection The air ionizer monitors the quantity of ions generated by itself, if the level
deteriorates, the needle check (NDL Check) indicator flashes on the air ionizer
control panel. The control panel is visible through the slot in the left hand safety
cover.
Figure 31-1 Air Ionizer Control Panel
If the NDL Check indicator flashes, one or more of the fourteen electrodes (7
cartridges on the array, each cartridge has two electrodes) may be dirty or faulty.
It is recommended that the electrodes are cleaned. If the ion level alarm
indicator continues to flash, replace all the electrodes. An electrode needle
cleaning kit is available contact ASM Customer Support for details.
0123456789
ABCDEF
0123456789
ABCDEF
0123456789
ZERO
FREQIDI/O MONITOR
OFF
TERM
ON
TERM
ON
I.C.C. CONDLEVEL
ION MONITOR
ION
ALM RC
+
-
View on Left Side of Machine
NOTE
Safety cover removed for clarity.
Needle Check Indicator
H
L
M
H
M
L
MANUAL
AUTO
MANUAL
LEVEL
Zero
Adjust
NDL
CHECK
+
SNSRSNSR
OK
MAINHV
-
ALARM
ION POWER
2
3
7
8
FREQ SELECT
6
7
8
5
4
3
6
7
5
4
3