TX机台季度保养 - 第30页
www.asm-smt.com

8 WF 2 TX-Series Maintenance Clean the conveyor, lifting tables and gantry cables 4 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T1
Wear Part: Consumables:
C3
www.asm-smt.com
1 Clean the gantry cables of the X-Axis. 2 Clean the gantry cables of the Y-Axis. 3 Move all gantries to the end limit at loca-
tion 1 and repeat steps 1 to 2 for the other
gantry.
4 Vacuum all loose components on and
around the whole PCB conveyor.

www.asm-smt.com

9 WF 2 TX-Series Maintenance Clean the stationary camera (CPP/ TH) 2 min 1 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
C2
www.asm-smt.com
1 Move all gantries to the end limit. 2 Remove the reject bin. 3 Take off the upper section of the station-
ary camera.
4 Remove any components. 5 Clean the slanted glass. 6 Refit the upper section of the camera.