AX501最新3.6x版英文操作手册 - 第41页

4022 593 51894 Operatin g Man ual 09.01 AX-301/501, AX-3/5 41 9 9.6 Log o ff Figure 53 Log off screen T o log off: • Sel ect (1). • Confirm with ’OK’ (2). 1 2

100%1 / 47
4022 593 51894 Operating Manual
09.01 AX-301/501, AX-3/5 40
9
9.4 Finish production
Finish production:
Prevents the machine from loading new boards.
Finishes production for boards already in the machine.
Ends production when the machine is empty.
Figure 51 Finish production
To finish production:
Select “Finish” production (1).
Confirm with “OK” (2).
9.5 Abort production
Abort production stops production immediately. Boards present in the
machine are not finished.
Figure 52 Abort production
To abort production:
Select “abort” (1).
To empty the machine select “remove automatically” (2a).
To leave the boards in the machine select
abort immediately” (2b).
Confirm with “OK” (3).
1
2
1
2b
2a
3
4022 593 51894 Operating Manual
09.01 AX-301/501, AX-3/5 41
9
9.6 Log off
Figure 53 Log off screen
To log off:
Select (1).
Confirm with ’OK’ (2).
1
2
4022 593 51894 Operating Manual
09.01 AX-301/501, AX-3/5 42
10
CHAPTER 10 Error Handling
10.1 Errors and warnings, recognition
A coloured border shown around the alarm button indicates a machine or
process malfunction:
Figure 54 Error indication
A red border indicates an error (1).
Machine stopped, error has to be solved before production can
continue.
Beeps and Blue lamp on lamp post turn on.
Figure 55 Warning indication
A yellow border indicates a warning (2).
Machine proceeds, but problem should be solved for optimal
operation.
10.2 Display errors
Figure 56 Alarm screen selection
Select ’Alarms’ (1).
Select ’Errors’ (2).
Use available information on:
- Module(s) causing error(s) (A).
- Details on error(s) (B).
- Help instructions on selected error (C).
- Camera view related to the error situation (D),
see section 10.2.1. Camera view.
- Access to diagnostics environment (E),
see section 10.3.1. Diagnostics toolbox.
Solve the problem on the machine.
1
2
2
3
1
A
B
D
C
E