AX501最新3.6x版英文操作手册 - 第9页
4022 593 51894 Operatin g Man ual 09.01 AX-301/501, AX-3/5 9 1 1.7 Safety devices Figure 3 Safety devices Locations o f safety devices ar e depicted in figure 4 an d figure 5 . Figure 4 Location of safety devices Safety …

4022 593 51894 Operating Manual
0
9.01 AX-301/501, AX-3/5 8
1
1.5 Danger, warning and caution
■ Danger
Danger indicates an imminently hazardous situation
which, if not avoided, will result in death or serious
injury.
A danger statement is displayed in this manner:
■ Warning
Warning indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
A warning statement is displayed in this manner:
■ Caution
Caution indicates a potentially hazardous situation
which, if not avoided, could result in minor or moderate
injury. It may also be used to alert against unsafe
practices.
A caution statement is displayed in this manner:
1.6 Safety stickers
Figure 1 Safety stickers
Figure 2 Location of safety stickers
HAZARD IDENTIFICATION
Hazard consequence.
Hazard avoidance.
DANGER
DANGER
HAZARD IDENTIFICATION
Hazard consequence.
Hazard avoidance.
WARNING
WARNING
HAZARD IDENTIFICATION
Hazard consequence.
Hazard avoidance.
CAUTION
CAUTION
Pictogram Category Meaning
1 WARNING DANGER, HIGH VOLTAGE
Contact may cause electric shock or
burn. Turn off & lock out system
before servicing.
2 WARNING DANGER OF CLAMPING
FINGERS
Serious injury to fingers.
Keep hands away from moving
parts.
1
2
2
2
2
2

4022 593 51894 Operating Manual
09.01 AX-301/501, AX-3/5 9
1
1.7 Safety devices
Figure 3 Safety devices
Locations of safety devices are depicted in figure 4 and
figure 5.
Figure 4 Location of safety devices
Safety device
Hazard
protected
Detection method
Machine condition
after safety device is
activated
1 Safety
interlock.
Hazardous
moving
parts.
Safety circuit interruption by
opening any (left or right)
transport cover.
All moving parts will be
stopped and power to
servo systems is turned
off.
2 Safety circuit interruption by
opening any robot.
3 Safety circuit interruption by
opening any safety cap.
4 Safety circuit interruption by
lowering any trolley.
5 Safety circuit interruption by
removing any trolley lift cover.
6 Emergency
stop button.
Hazardous
moving
parts.
Safety circuit interruption by
pushing the emergency stop
button.
All moving parts will be
stopped and power to
servo systems is turned
off.
7 Electrical
disconnect.
Hazardous
voltage.
Mains power supply to the
machine interruption by turning
the electrical main switch to 'off'.
All power to the machine
is turned off.
8Air
disconnect.
Hazardous
air
pressure.
Main air supply to the machine
interruption by turning the main
air switch to 'off'.
All air pressure to the
machine is turned off,
and present air
pressure is released
safely.
6
6
7
8
1
1
2
3
4
5
6
6
Safety interlock

4022 593 51894 Operating Manual
09.01 AX-301/501, AX-3/5 10
1
Figure 5 Safety devices, rear
Pull the red emergency stop buttons (6) to release the
emergency.
Lock the electrical main switch (7) and the air main
switch (8) by a padlock to avoid unauthorized use.
1.8 Noise levels
Figure 6 Noise levels
1.9 Emergency contact
In case assistance is needed during an emergency
situation, contact the regional Assembléon
organization.
Figure 7 Numbers
1.10 Liability
Assembléon will not be liable for any costs, damages or
personal injuries if the machine is not used according
to the safety rules given in this manual.
Instructions written in English are original instructions.
Instructions written in other languages are a
translation of the original.
Location Noise level
Average sound-pressure level measured at 3 operator
positions at height = 1.6 m and distance = 1 m
≤ 75 dB(A)
Sound pressure at operator’s position ≤ 72 dB(A)
Average environmental noise level during measurement 58 dB(A)
5.5
8
67
Region Number
Asia +65-62-61-4611
America's 1-800-474-4547
Europe +31-20-5040679