4 Operation 4.16 Performing a self-test User Manual SIPLACE Linear Dipping Unit E 12/2018 55 4.16 Performing a self-test ► In the station software, select the Single functions view (1) and then the Subsys- tems area (2)…

100%1 / 68
4 Operation
4.15 Testing new flux types
54 User Manual SIPLACE Linear Dipping Unit E 12/2018
Performing the measurement
Measurement 1
Hold the measuring device with your thumb and forefinger on its handle.
(1) Place the measuring device with the point which is opposite the zero value of the scale
onto the flux surface and press down to the base of the cavity.
(2) Apply slight pressure and roll the measuring device in one direction to the zero value (3).
Take the measuring device vertically up and out of the flux.
Determine on the middle roller the point (2) where the flux starts to coat the middle roller.
Read the value on the scale at this point.
Measurement 2
Repeat the measurement by rolling the measuring device in the opposite direction as far as
the zero value.
Read the value shown on the scale.
Calculate the mean value of both measuring results.
4.15 Testing new flux types
If you use a new flux, then proceed as follows during the test phase:
Calculate the relevant cavity for the product.
Place the corresponding dip plate in the LDU.
Fill in the flux.
Set the application speed as slow.
Increase the application speed in steps.
While doing this, observe the flux surface.
Reduce the application speed again, if waves, dips or irregularities are formed on the surface.
Select a long dwell time. This can be reduced later to achieve higher cycle times.
Select a slow start for the upwards movement of the placement head after dipping. This en-
sures that the component is not lost in the flux.
4 Operation
4.16 Performing a self-test
User Manual SIPLACE Linear Dipping Unit E 12/2018 55
4.16 Performing a self-test
In the station software, select the Single
functions view(1) and then the Subsys-
tems area (2).
Select the Location (3) on which the LDU
is set up.
Select the Feeder area (1).
Select the LDU in the list of set up feeders
(2).
Click on the Details…button (3).
Click on the Self-test button.
The LDU performs a self-test.
4 Operation
4.17 Operating the control unit
56 User Manual SIPLACE Linear Dipping Unit E 12/2018
4.17 Operating the control unit
Logging off
Use the Up (1) or Down key (2) to select the operating mode P0.
Press the Select key (3).
The LDU will be logged off and unlocked from the placement machine.
Remove the LDU from the changeover table.
Starting a reference run
Use the Up (1) or Down key (2) to select the operating mode P1.
Press the Select key (3).
The LDU performs a reference run.
Refreshing the dipping medium
Select with the Up (1) or Down key (2) the operating mode P2.
Press the Select key (3).
The LDU performs a squeegee movement.