00198521-01_UM_LDU_E_EN.pdf - 第7页
1 Introduction 1.2 Important notes on this user manual User Manual SIPLACE Linear Dipping Unit E 12/2018 7 1.2 Important notes on this user manual 1.2.1 Contents and filing of this user manual This user manual contains b…

1 Introduction
1.1 Module Description
6 User Manual SIPLACE Linear Dipping Unit E 12/2018
1.1.4 Requirements and restrictions
●
The LDU E can be used on all E by SIPLACE placement machines.
●
A maximum of 2 LDUE can be set up on a changeover table.
●
The LDU E can be used with all placement heads of E by SIPLACE placement machines.
●
For operating the LDU E, station software version 711.0 or higher and line software version
15.0 or higher are required.
●
The LDUE can handle component sizes from 0.2mm x 0.2mm up to 42mmx42mm.
●
Using the LDU E in the placement process reduces the placement rate of a machine.
●
When dipping components, no placement data are generated for the Operator Information
System (OIS).
1.1.5 Technical data
Dimensions (L x W x H) 629mm x 105mm x 202mm
Weight 10kg
Power consumption 24VDC – 30VDC, 2A (60W)
Max. noise emission 61 dB (A)
Temperature range (storage) from -25 °C to +55 °C
Temperature range (operation) from +15 °C to +35 °C
Atmospheric humidity (storage) ≤ 95%
Atmospheric humidity (operation) 30% - 75% (on average not exceeding 45%)
1.1.6 Environmentally-friendly disposal of materials and components
SIPLACE products are manufactured using only materials and parts that can be easily separated
and disposed of in an environmentally-friendly way.
NOTICE
Observe the applicable regulations
The company operating the system has sole responsibility for the proper, environmentally-
friendly disposal of machines, working materials, consumable materials and wear parts.
► Please observe your national statutory provisions for waste disposal and environ-
mental protection.
1.1.7 Electromagnetic compatibility (EMC)
All SIPLACE products are designed and tested for professional use in industrial applications. Elec-
tromagnetic compatibility in terms of the emission of interference cannot be guaranteed in any
other environment.
1.1.8 Use of original SIPLACE accessories and spare parts
Only use original spare parts and authorized accessories. The use of other parts will affect safety
and will invalidate the liability for any consequential damage.

1 Introduction
1.2 Important notes on this user manual
User Manual SIPLACE Linear Dipping Unit E 12/2018 7
1.2 Important notes on this user manual
1.2.1 Contents and filing of this user manual
This user manual contains basic information that must be observed when setting up, operating and
maintaining the device. The service engineers, qualified staff, operators and users plus system
owner must therefore read it before commencing installation and commissioning. The manual must
be kept permanently accessible where the device is used.
In addition, the system owner has to ensure that all members of the staff have fully understood the
contents of the user manual.
1.2.2 Danger notes
WARNING
Danger notes
► A thorough knowledge of the relevant part of this user manual is required before carry-
ing out any work on the LDU.
► All work must be carried out by appropriately trained and qualified personnel.
► All warnings, cautions and hazard notes must be observed.
► Please also read and follow the instructions in chapter 2 "Operating safety" of the user
manual.
1.2.3 Manufacturer's/Supplier's liability
We hereby confirm that the contents of this user manual are of a descriptive and explanatory
nature only and do not contain any contractual conditions or guaranties. The liability and obliga-
tions assumed by ASM Assembly Systems GmbH & Co. KG can be found exclusively in the relev-
ant contract agreement concerning the supply of the device described in this manual. This applies
in particular to all statements regarding performance or service life and the agreed liability for faults
or defects. The provisions of the contract regarding the liability for faults or defect are neither exten-
ded nor restricted by any statements in this user manual.
1.2.4 Release history
Document
SIPLACE Linear Dipping Unit E
User manual
Edition Amendments
12/2018 Initial release
1.2.5 Further information
1.2.5.1 How to get information
If you have any questions about this manual or require more information on specific topics, please
contact your local SIPLACE branch. Or contact us directly:
ASM Assembly Systems GmbH & Co.KG
Rupert-Mayer-Str. 44
81379 München

1 Introduction
1.2 Important notes on this user manual
8 User Manual SIPLACE Linear Dipping Unit E 12/2018
1.2.5.2 SIPLACE on the World Wide Web (WWW)
Log in to our SIPLACE® homepage at http://www.asm-smt.com.
You can choose between the German and English version.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can also access the MySIPLACE user group. Here you can call
up special information about our placement systems, e.g.
●
technical documentation
●
technical information
●
spare parts lists etc.
Registration for the MySIPLACE user group is very simple:
► At the head of the web site, click on
and then on the Register
link.
► Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with user name and password.