1 - 4 S tudent Guide SIPLACE HF/HF3 4 Services to the machine Edition 09/2005 4 4.1.1 Overview power supply Fig. 4.1 - 2 main power supply unit identical in original - and ’A’ version of the HF-Machine Legend (1) DC /DC …

100%1 / 596
1 - 3
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
3
4 Services to the machine
4.1 Overview
the figure below shows the position of the units which create and distribute the supply voltages
needed to operate the system
power supply unit containing main distributor (pos. 1)
section distributor section 2 (pos. 2)
pneumatic unit (pos. 3)
section distributor section 4 (pos. 4)
Fig. 4.1 - 1 HF/HF3 main units identical at original - and ’A’ version of HF-machine
P
o
w
e
r
s
u
p
p
l
y
Section 4
Section 2
P
n
eu
m
at
ic
U
n
it
3
1
4
2
1 - 4
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
4
4.1.1 Overview power supply
Fig. 4.1 - 2 main power supply unit identical in original - and ’A’ version of the HF-Machine
Legend
(1) DC/DC Converter 24 V (4) Fuse F5 for star axis
(2) DC/DC Converter 5 V at HFand 5V/24V at HF3 (5) Fuse F11 for inrush current limiter
(3) Safety combination relay K6
1
2
3
4
5
main distributor main
power supply
Inrush current limiter:
a: transformer: EST
b: servo: Ess
transformer T2
transformer T1
T1
T2
Fuse F61 - fuse F142
Units Identification Contact Voltages
X100 main power supply L1, L2, L3 3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
X102 service socket 115 VAC / 220 VAC / 230 VAC / 240 VAC
Q1 main switch 1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
Q2 motor circuit breaker 1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
K1 main contactor 1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
K2 contactor 1, 3, 5 u.
2, 4, 6
3 x 177 VAC
K3 contactor 1, 3, 5 u.
2, 4, 6
3 x 177 VAC
K4 contactor 1, 3, 5 u.
2, 4, 6
3 x 177 VAC
1 - 5
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
5
K5 contactor A1(+)– A2 (-)
1,2
3,4
5,6
24VDC
24 VDC to GND
24 VDC to GND
24 VDC to GND
K6 (SSK) safety combination L+, X3, X5 24 VDC to GND
F1 fuse service socket;
1-pol.
1, 2 115 VAC / 220 VAC
230 VAC / 240 VAC
F2 fuse co-table;
3-pol.
1, 3, 5 u.
2, 4, 6
3 x 36 VAC
F4 fuse X- / Y-axis;
3-phase.
1, 3, 5 u.
2, 4, 6
3 x 177 VAC
F5 fuse star-axis;
1-phase
1, 2 145 VDC to GND
F6 fuse Z- and DP-axis;
1-phase.
1, 2 39 VDC to GND
F7 fuse secundary circuit;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 230 VAC
F8 fuse PCB-transport;
1-phase
1, 2 33 VDC to GND
F10 fuse rectifier V7 and V70;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 39 VAC
F11 fuse inrush current limiter
1-phase
1, 2 33,6 VDC to GND
F12 fuse illumination
1-pol.
1, 2 52 VDC to GND
F13 fuse monitor;
1-pol.
1, 2 26 VDC to GND
F14 fuse Y-motor cooling device
1-phase
1, 2 26 VDC to GND
F61 / F62 fuse rectifier V4 3 x 28 VAC
F81 / F82 fuse rectifier V5 3 x 23,8 VAC
F111 / F112 fuse rectifier V8 3 x 23,8 VAC
F131 / F132 fuse rectifier V10 3 x 19,7 VAC
F141 / F142 fuse rectifier V11 3 x 18,7 VAC