SG_FSE_SiplaceHF_HF3_00193901-05_eng - 第120页

1 - 6 S tudent Guide SIPLACE HF/HF3 4 Services to the machine Edition 09/2005 6 Notes

100%1 / 596
1 - 5
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
5
K5 contactor A1(+)– A2 (-)
1,2
3,4
5,6
24VDC
24 VDC to GND
24 VDC to GND
24 VDC to GND
K6 (SSK) safety combination L+, X3, X5 24 VDC to GND
F1 fuse service socket;
1-pol.
1, 2 115 VAC / 220 VAC
230 VAC / 240 VAC
F2 fuse co-table;
3-pol.
1, 3, 5 u.
2, 4, 6
3 x 36 VAC
F4 fuse X- / Y-axis;
3-phase.
1, 3, 5 u.
2, 4, 6
3 x 177 VAC
F5 fuse star-axis;
1-phase
1, 2 145 VDC to GND
F6 fuse Z- and DP-axis;
1-phase.
1, 2 39 VDC to GND
F7 fuse secundary circuit;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 230 VAC
F8 fuse PCB-transport;
1-phase
1, 2 33 VDC to GND
F10 fuse rectifier V7 and V70;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 39 VAC
F11 fuse inrush current limiter
1-phase
1, 2 33,6 VDC to GND
F12 fuse illumination
1-pol.
1, 2 52 VDC to GND
F13 fuse monitor;
1-pol.
1, 2 26 VDC to GND
F14 fuse Y-motor cooling device
1-phase
1, 2 26 VDC to GND
F61 / F62 fuse rectifier V4 3 x 28 VAC
F81 / F82 fuse rectifier V5 3 x 23,8 VAC
F111 / F112 fuse rectifier V8 3 x 23,8 VAC
F131 / F132 fuse rectifier V10 3 x 19,7 VAC
F141 / F142 fuse rectifier V11 3 x 18,7 VAC
1 - 6
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
6
Notes
1 - 7
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
7
4.2 Power Supply on HF
4.2.1 Naming Convention of Connectors and Cables
The wiring on HF is highly structured. Every cable, connector, distributor uses an exact term,
which is dedicated to the sections and units in question:
The name convention and the systemacy is explained at the original HF-Machine type; this is ba-
sically valid for all the HF-machine series.
Section 2: term q+ 4
Main-distributor section 2: term X1qa, X2qa, X3qa, ...
CAN I/O module: term: term X1
qb, X2qb, X3qb, ...
Vision DC/DC converter: term X1
qc, X2qc, X3qc, ...
Vision control unit: term X1
qd, X2qd, X3qd, ...
Section 4: term r+ 4
Sub-distributor section 4: term X1ra, X2ra, X3ra, ...
CAN I/O module: term: term X1
rb, X2rb, X3rb, ...
Vision DC/DC converter: term X1
rc, X2rc, X3rc, ...
Vision control unit: term X1
rc, X2rd, X3rd, ...
Placement head gantry 1: term a+ 4
Gantry distributor: 00 353593 aa
Gantry interface: 00 363330
ab
Head interface: 03000900
ac
Vision board: 03 321469
au
Placement head gantry 3: term b+(up to Machine MA.No. xx / from MA .No. xx is the term c+) 4
Gantry distributor: 00 353593 ba
Gantry interface: 00 363330
bb
Head interface: 03000900
bc
Vision board: 03 321469
bu
Placement head gantry 4 (HF3): term d+ 4
Gantry distributor: 00 353593 da
Gantry interface: 00 363330
db
Head interface: 03000900
dc
Vision board: 03 321469
du
Computer unit: X1
p+