1 - 13 S tudent Guide SIPLACE HF/HF3 Edition 09/2005 4 Servic es to the machine 13 4.2.4.1 Input V olt age Fig. 4.2 - 5 input voltage Legend Q1: main switch Q2: motor circuit breaker K1: main contactor and inru sh curren…

100%1 / 596
1 - 12
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
12
Fig. 4.2 - 4 main power supply unit
Legend
F7 fuse secundary circuit;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 230 VAC
F8 fuse PCB-transport;
1-phase
1, 2 33 VDC to GND
F10 fuse rectifier V7 and V70;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 39 VAC
F11 fuse inrush current limiter
1-phase
1, 2 33,6 VDC to GND
F12 fuse illumination
1-pol.
1, 2 52 VDC to GND
F13 fuse monitor;
1-pol.
1, 2 26 VDC to GND
F14 fuse Y-motor cooling device
1-phase
1, 2 26 VDC to GND
F61 / F62 fuse rectifier V4 3 x 28 VAC
F81 / F82 fuse rectifier V5 3 x 23,8 VAC
F111 / F112 fuse rectifier V8 3 x 23,8 VAC
F131 / F132 fuse rectifier V10 3 x 19,7 VAC
F141 / F142 fuse rectifier V11 3 x 18,7 VAC
(1) DC / DC Converter 24 V (4) Fuse F11 for inrush current limiter
(2) DC / DC Converter 5 V (HF)and 24V (HF3) (5) Fuse F6 for star axis
(3) Safety combination relay K6
1
2
3
4
5
main distributor main
power supply
Inrush current limiter:
a: transformer: EST
b: servo: Ess
transformer T2
transformer T1
T1
T2
Fuse F61 - fuse F142
1 - 13
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
13
4.2.4.1 Input Voltage
Fig. 4.2 - 5 input voltage
Legend
Q1: main switch
Q2: motor circuit breaker
K1: main contactor and inrush current limiter for T1
T1: transformer 1
T2: transformer 2
Please Note: After the transformer T1 and T2, the main power potential end and only secundary
voltages supply the machine
Q1
Q2
K1
3 phase
U
V
W
T1
U
V
W
T2
3x 230 V
Ínrush current
limiter for T1
L1
L2
L3
power
filter
1 - 14
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
14
4.2.4.2 Transformer 1
The main reason for the transformer T1 is to power the X/Y and star axis, protected by F4. Con-
tactors K2, K3 and K4 illustrate fixed elements of the electrical safety concept. In a fault event, e.g.
open cover, the servos are disconnected from the energy.
4
The power supply unit provides the following supply voltages: 4
Primary Transformer T1 4
250 VDC for the servo amplifiers of the x and y axes.
150 VDC servo amplifiers of the star axis.
34 VDC for the inrush current limiter servo
52 VDC for the DC/DC converters in the main power unit
52 VDC for camera illumination and computer unit DC/DC converter
Fig. 4.2 - 6 overview transformer T1
T1
main distributor power supply
X/Y servo
U7
U70
250 VDC
52 VDC
52 VDC
24 VDC
52 VDC
5 VDC
F11
F12
U6
U60
power fail Twin head
U8
F10
34 VDC
K2 K3
K4
F4
K2 K3
K4
U1
U2
F5
U3
150 VDC
X/Y servo
250 VDC
star servo
SZ1 (Inrush
current delay)
3 phase
3 phase
3 phase
3 x 230 V
T2
F7
DC/DC
computer unit
52 VDC
L1
L2
L3
DC/DC axis
unit
camera
illumination
P&P camera
power fail C&P head
main power supply
U 20
U 30