1 - 28 S tudent Guide SIPLACE HF/HF3 6 Collect &Place-He ad / DLM2 Edition 09/2005 28 6.3.9 Pick up 7th component Fig. 6.3 - 9 Pick up 7th component 6.3.10 Pick up 8th component Fig. 6.3 - 10 Pick up 8th component St…

100%1 / 596
1 - 27
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
27
6.3.7 Pick up first Component
Fig. 6.3 - 7 Pick up first component
6.3.8 Pick up 6th component
Fig. 6.3 - 8 Pick up 6th component
Star position 0°
Vision system: no action
DP-station: turn nozzle 5 to Pick up angle
pick up / placement station: pick up first component
component sensor: during the next Star step the
nozzle length of segment 3 is measured
The remaining nozzles now pick up the components as
the star is stepped.
Star position 150°
Vision system: no action
DP-station: turn nozzle 10 to Pick up angle
pick up / placement station: pick up 6th component
synchronization: communication with MVS for the
optical centering of components.
component sensor: during the next Star step the
nozzle length of segment 8 is measured
1 - 28
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
28
6.3.9 Pick up 7th component
Fig. 6.3 - 9 Pick up 7th component
6.3.10 Pick up 8th component
Fig. 6.3 - 10 Pick up 8th component
Star position 180°
Vision system: component on segment 1 is cen-
tered.
DP-station: turn nozzle 11 to Pick up angle
pick up / placement station: pick up 7th component
synchronization: communication with MVS for the
optical centering of components.
component sensor: during the next Star step the
nozzle length of segment 9 is measured
Star position 210°
Visionsystem: component on segment 2 is centered.
DP-station: nozzle on segment 12 is turned to pick up
angle.
pick up / placement station: pick up 8th componen
component sensor: during the next Star step the noz-
zle length of segment 10 is measured
1 - 29
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
29
6.3.11 Pick up 9th Component
Fig. 6.3 - 11 Pick up 9th component
The process continues with the remaining components being picked up, centred and turned to the
corrected placement angle.
6.3.12 Component recognition at the 1
st
Segment in Component Sensor
Fig. 6.3 - 12 Pick up 11
th
component and comp. recognition at 1
st
segment
Star position 240°
Vision system: optical centering of the 3rd component
DP-station: turn 1st component to the placement an-
gle
pick up / placement station: pick up 9th component
component sensor: during the next Star step the noz-
zle length of segment 11 is measured
Star turns to -> 330°
During the Star-axis is turning from 300.000 to
330.000 Digit.
the component sensor (option) measures the pres-
ence resp. the height of the component.
The measured length before placement have to be
larger than "nozzle length + comp.height -
comp.height tol."
The measurement in the component sensor hap-
pens at full movement of the star axis -"on the fly"- .
A defective component is rejected at the next