SG_FSE_SiplaceHF_HF3_00193901-05_eng - 第242页

1 - 42 S tudent Guide SIPLACE HF/HF3 6 Collect &Place-He ad / DLM2 Edition 09/2005 42 6.3.31 Placing component det ailed: Z-axis upwards Fig. 6.3 - 28 Placing component detailed: Z-axis upwards LB bottom switch: – En…

100%1 / 596
1 - 41
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
41
6.3.30 Placing component detailed: Z-axis downwards
Fig. 6.3 - 27 Placing component detailed: Z-axis downwards with light barrier mode
The placement force is defined by the spring in the sleeve ~2.4 N at 12 nozzle head
End signal X-, Y-, Star-axis:
all 3 end signal available
vacuum check before placement is executed (alternatively the component check in the
comp.sensor).
component on the nozzle?
Z-axis starts:
Z-axis positioning downward
LB above switches:
solenoid air kiss ON
enable LB bottom
LB bottom switches:
End signal positioning downward;
valve drive, pick up- placement position, to air kiss
1
2
1
1
10
9
8
7
6
5
1
2
3
4
1 - 42
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
42
6.3.31 Placing component detailed: Z-axis upwards
Fig. 6.3 - 28 Placing component detailed: Z-axis upwards
LB bottom switch:
End signal positioning downward; valve drive, pick up- placement position, to air kiss;
Measure air kiss pressure component placed
Start term to move up
Z-axis started:
Z-axis positioning upwards
LB above:
reset solenoid for air kiss
reset LB bottom signal
enable start for gantry axes
Z-axis end signal (Z-axis on 0-position):
(503) vacuum check after placement
enable start for Star-axis
1
2
1
1
10
9
8
7
6
5
1
2
3
4
1 - 43
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
43
6.3.32 Placing component detailed: Z-axis downwards
Fig. 6.3 - 29 Placing component detailed: Z-axis downwards with current sensor mode
A placement force of 3 to 5 N at the C&P head.
End signal X-, Y-, Star-axis:
all 3 end signal available
vacuum check before placement is executed (alternatively the component check in the
comp. sensor).
component on the nozzle?
Z-axis starts:
Z-axis positioning downward
LB above switches:
solenoid air kiss ON
enable LB bottom
LB bottom switches:
valve drive, pick up- placement position, to air kiss
current sensor on servo amplifier trigger:
End signal positioning downward;
6.3.32.1 Advantage of placement with increased placement force
This "increased placement force" at placement offer you (on all stations):
a good contact to the solder paste for large components / large contact surfaces to the PCB.
A delay of ~20 ms compared to the standard placement cycle.
1
2
1
1
10
9
8
7
6
5
1
2
3
4