SG_FSE_SiplaceHF_HF3_00193901-05_eng - 第245页

1 - 45 S tudent Guide SIPLACE HF/HF3 Edition 09/2005 6 Colle ct &Place-Head / DLM2 45 6.3.34 Special mode "st a rt slow" Z-axis upwards Fig. 6.3 - 31 Special mode St art sl owly Z-axis upwards after placeme…

100%1 / 596
1 - 44
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
44
6.3.33 Special mode: "brake slow" mean: move slowly into (Z)-position
Fig. 6.3 - 30 Special mode brake slow Z-axis downwards
This special mode is ONLY on SC/MC 503 station and higher.
End signal X-, Y-, Star-axis:
all 3 end signal available
vacuum check before placement is executed (alternatively the component check in the
comp.sensor).
component on the nozzle?
Z-axis starts:
Z-axis positioning downward
LB above switches:
solenoid air kiss ON
enable LB bottom
special mode: 44 digit (1 mm) before target Z-height the Z-axis move with minimum speed
LB bottom switches:
End signal positioning downward;
valve drive, pick up- placement position, to air kiss
6.3.33.1 Advantage of special mode "brake slow" -move slow into Z-target position
This "break slow" at placement offer you (on SC/MC 503 stations and higher):
a bubble free contact of the FLIP-CHIP component into a filling material.
A delay of ~20 ms compared to the standard placement cycle.
1
2
1
1
10
9
8
7
6
5
1
2
3
4
1 - 45
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
45
6.3.34 Special mode "start slow" Z-axis upwards
Fig. 6.3 - 31 Special mode Start slowly Z-axis upwards after placement
This special mode is ONLY on SC/MC 503 station and higher.
LB bottom switch:
End signal positioning downward; valve drive, pick up- placement position, to air kiss;
Measure air kiss pressure component placed
Start term to move up
Z-axis started:
Z-axis positioning upwards for 44 digit with start speed. (The vacuum inside nozzle had
gone)
LB above:
reset solenoid for air kiss
reset LB bottom signal
enable start for gantry axes
Z-axis end signal (Z-axis on 0-position):
enable start for Star-axis
(503) vacuum check after placement
6.3.34.1 Advantage of special mode "start slow" -start slow Z-axis upwards after placement
This "start slow" after placement offer you (on SC/MC 503 stations and higher):
The danger to take a component after placement from the PCB is reduced.
A delay of ~20 ms compared to the standard placement cycle.
1
2
1
1
10
9
8
7
6
5
1
2
3
4
1 - 46
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
46
6.3.35 Special mode: Z-Axis downwards with waiting time at placement
Fig. 6.3 - 32 Special mode: Z-Axis downwards with waiting time at placement
End signal X-, Y-, Star - Axis:
all 3 end signal available
vacuum check "before placement" is executed component on the nozzle?
(or signal from component sensor)
Z-axis start:
Z -Axis positioning downward positioning mode -absolute-
LB above switch:
Electro magnetic valve air kiss ON
enable LB bottom
Light barrier bottom trigger:
End signal positioning downward
valve drive, pick up- placement position, to air kiss
Special mode" Waiting time down":
End signal Z-axis downward the waiting time will be started of the MC
After the waiting tim is the air kiss measured
Positioing mode for Z-axis upwards is started
1
2
11
10
9
8
7
6
5
1
2
3
4