1 - 68 S tudent Guide SIPLACE HF/HF3 6 Collect &Place-He ad / DLM2 Edition 09/2005 68 Fig. 6.4 - 17 Z-Limit stop check and adjust ➠ Loosen t he screw of the Z limit stop.( Fi g. 6.4 - 1 7) ➠ Clamp a 15/100 mm feeler …

1 - 67
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
67
6.4.7.3 Settings
➠ Switch off the machine. The setting can, however, be made directly on the machine.
➠ The star gauge for setting the Z limit stop is mounted on the C&P head in exactly the same way
as the zero point gauge for the star.
➠ Remove the segment 1 from the star and turn the star, so that the gauge pin is inserted on
segment 1.
Fig. 6.4 - 16 Z-Limit stop gauge mounted
Please Note:
For DLM 1 heads an additional adapter must be mounted for the gauge.
– The star gauge ensures that the star is at the correct position and the Z axis is pushed up-
wards.
➠ To obtain better access to the Z limit stop, you should unscrew the cable clip on one side and
twist it away. Push the ribbon cable carefully aside.
➠ Use the 5/100 mm feeler gauge to check that it can be moved freely (without resistance) bet-
ween the Z limit stop and the clamp. (Fig. 6.4 - 17)
If this is not the case, the limit stop must be adjusted.

1 - 68
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
68
Fig. 6.4 - 17 Z-Limit stop check and adjust
➠ Loosen the screw of the Z limit stop.( Fig. 6.4 - 17)
➠ Clamp a 15/100 mm feeler gauge between the Z limit stop and the clamp. Push the Z limit stop
down gently with a screwdriver and tighten the screw again.
➠ The 15/100 mm feeler gauge should now be difficult to withdraw.
➠ Use the 5/100 mm feeler gauge to check again that it can be moved freely (without resistance).
If this is not the case, the adjustment must be repeated.
Please Note:
When removing the gauge, make sure that the gauge pin is first withdrawn and then the star
gauge is removed. If this is not done, the gauge can wedge between the segments and can pos-
sibly damage the segments!
. 6
6.4.8 Light Barrier, Bottom Position
Plesae Note:
In order to adjust the light barrier, use a parallel pin and adjust it to a distance of 1.0 mm to the
sleeve.
Z-Limit stop
Feeler gauge
Clamping device

1 - 69
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
69
6.4.9 Determination of Zero Point Correction Star-Axis C&P Head
Fig. 6.4 - 18 Flow chart zero point correction
Menue C&P Heads
Select referring C&P Head
Menue Axes
Select Star axis
Positions
Zero point correction (ZPC) = 0
edit and accept
Axis reference run
disable Star / Z* Axis at axis
controller
Remove sleeve from segment 1
Turn segment 1 to bottom position
Mount Star axis Zero point gauge,
Insert fixing pin into gauge
DLM2 lower Z-Axis, that fixing pin
engage at segment
Select DP- and Star-Axis again
Enter actual position as new
Zero point correction (ZPC)
*
Remove Star zero point gauge
Insert sleeve
Enable Star (Z*) Servo
Execute Axis reference run
check position of the new Zero point-
correction (Segment 1 down)
Save machine data
End
start SITEST
* for DLM2 at HF-Machine:
* ZPC for HF-Machine: divide
actual Position by 2.5
* for DLM2 at HF-Machine: