SG_FSE_SiplaceHF_HF3_00193901-05_eng - 第286页

1 - 86 S tudent Guide SIPLACE HF/HF3 6 Collect &Place-He ad / DLM2 Edition 09/2005 86 6.6.3.4 Example for dynamic with the control signal of the V nom. output The Axis dynamic of the S tar axis is checked with S tar …

100%1 / 596
1 - 85
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
85
6.6.3.3 Test setup with SAT-Box
Please Note:
For checking of the dynamics with the aid of the SAT-Box please use the official Adjustment ma-
nual. 6
Fig. 6.6 - 6 Test set up SAT-Box
Legend outputs Siplace Axis Tester to oscilloscope channels
(1) Nominal current (Vreg)
not connected to the scope for HF
(2) uncommutated nominal current
connect to CH2
(3) Deviation of position connect to CH1 (4) End signal connect to CH 3
Axis unit error
Servo ON
Initialize
Counter error
Zero puls
End signal
Interface:
Test adapter,
Axis test box,
SAT-Box
2
4
1
3
1 - 86
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
86
6.6.3.4 Example for dynamic with the control signal of the Vnom. output
The Axis dynamic of the Star axis is checked with Star step continuos run. At Vnominal output of
the Axis tester pass a motor current signal. (Control signal1) The uncommutated nominal current
signal (Signal 3) show the friction of the axis system it show also increased friction.
The positioning time for the Star axis step is 70 ms (6 segment C&P head) and for the 12 segments
C&P head 46 +/-3 ms.
Fig. 6.6 - 7 Dynamic signals Star axis for excample 6 segment C&P head
Legend
SITEST: 6
Select "C&P heads" ==> "Select head" ==>"Axis functions" ==> "Select
Star-axis" ==> "Continuous run Star" ==> Edit: Waiting time "500 ms" ==> "Accept".
If necessary, press the START button.
(1) Control signal (Axis testbox V
nom.) (2) Uncommutated Current signal Axis adapter
(3) Position of deviation (4) End signal
1
2
3
4
1 - 87
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
87
12 segment C&P head DLM2 - signal for Star axis
6
Fig. 6.6 - 8 Dynamic signals Star-Axis 12segment C&P head DLM2
6 segment C&P head DLM2 - signal for Star axis 6
6
Fig. 6.6 - 9 Dynamic signals Star axis 6 segment C&P head DLM2
Please Note:
If the positioning time to slow, please check the friction of the distributor disk and the magnetic
neutral position of the star motor. 6
Current nominal
Deviation of pos.
End signal
10ms/Div
2V/Div
500mV/Div
Positioning time: 46ms +/- 3 ms 1 Star step= 30000 Digits = 30°degree
Positioning time: 70ms +/- 3 ms 1 Star step= 60000 Digits = 60°degree
Current nominal
Deviation of pos.
End signal
10ms/Div
2V/Div
500mV/Div