1 - 14 S tudent Guide SIPLACE HF/HF3 7 TWIN-Head Edition 09/2005 14 7.3.4 Prep are pick up process module 2 7.3.4.1 Pick up component module 2 Pick up with module 1 finished – St art X / Y Axis to Pick up position at fee…

100%1 / 596
1 - 13
Student Guide SIPLACE HF/HF3
Edition 09/2005 7 TWIN-Head
13
7.3.3.1 Pick up component module 1
Z-Axis position downwards with Standard Pick up
mode at 2 N Pick up force.
At contact with the component the force increase up
to the programmed value.
At this force level the End signal is triggered and the
Vacuum controlling is activated.
When Vacuum threshold ‘Pick up’ is measured the Z-
Axis movement upwards start with Standard-position-
ing mode.
communication to comp. table ‘index Feeder’ when
the Z-Axis reached the "safety height position.
At end signal Z-Axis top -> Vacuum check ‘comp. on
nozzle’
Turn with D-Axis the component to the placement an-
gle.
Prepare pick up with module 2
1 - 14
Student Guide SIPLACE HF/HF3
7 TWIN-Head Edition 09/2005
14
7.3.4 Prepare pick up process module 2
7.3.4.1 Pick up component module 2
Pick up with module 1 finished
Start X / Y Axis to Pick up position at feeder
track.
Start D2 Axis to set the Pick up angle during
X / Y positioning ..
communication to comp. table ‘Feeder ready’
opens component flap.
Z-
M
o
t
o
r
D-Motor
Z-Axis position downwards with Standard Pick up
mode at 2 N Pick up force.
At contact with the component the force increase up
to the programmed value.
At this force level the End signal is triggered and the
Vacuum controlling is activated.
1 - 15
Student Guide SIPLACE HF/HF3
Edition 09/2005 7 TWIN-Head
15
7.3.5 Component centering module 1 and 2
When Vacuum threshold ‘Pick up’ is measured the Z-
Axis movement upwards start with Standard-position-
ing mode.
Communication to comp. table ‘index Feeder’ when
the Z-Axis reached the "safety height" position.
At end signal Z-Axis top -> Vacuum check ‘comp. on
nozzle’
Turn with D-Axis the component to the placement an-
gle.
Prepare optical centering with module 1
Start X / Y Axis to move module 1 to camera position.
Start Z-Axis to move Bottom side of comp. to focus level.
‘flash’ IC-camera illumination
Move Z-Axis again upwards.
centering 1st component (near placement angle) is finished
Start X / Y Axis to move module 2 to camera position.
Start Z-Axis to move Bottom side of comp. to focus level.
‘flash’ IC-camera illumination
Move Z-Axis again upwards.
centering 2nd component (near placement angle) is finished