1 - 18 S tudent Guide SIPLACE HF/HF3 7 TWIN-Head Edition 09/2005 18 Notes

1 - 17
Student Guide SIPLACE HF/HF3
Edition 09/2005 7 TWIN-Head
17
TWIN- head - View for D-Axis 90 degree
7
Fig. 7.6 - 13 Dynamic signals D-axis 90 degree rotation
TWIN- head - View for D-Axis 180 degree
Fig. 7.6 - 14 Dynamic signals D-axis 180 degree rotation
Positioning time:approx. 150ms +/- 20ms, Distance 90000 digits
Current nominal
Deviation of pos.
End signal
200mV/Div
500mV/Div
50ms/Div
5V/Div
Positioning time: approx.190ms +/- 20ms Distance180000 digits
Current nominal
Deviation of pos.
End signal
200mV/Div
500mV/Div
50ms/Div
5V/Div

Student Guide SIPLACE HF/HF3
Edition 09/2005 Contents
1
Chapter
Table of Contents
8 Component handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
8.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
8.1.1 Component changeover table (COT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
8.1.2 Pneumatic tape cutter and empty tape duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
8.2 Component changeover table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
8.2.1 Structure of the component table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
8.2.2 Function description of the component changeover table. . . . . . . . . . . . . . . . . . . . . . 6
8.2.2.1 Docking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8.2.2.2 Undocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8.2.2.3 Adjustment pneumatic cylinder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
8.2.2.4 Docking unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8.2.3 Adjustment the COT height. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8.2.4 Optionally extension on the COT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8.2.4.1 Tape reel holder for the 3th reel at the 3x8mm S-Feeder . . . . . . . . . . . . . . . . . 10
8.2.4.2 Compressed air supply for Bulkcase feeder. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8.2.4.3 Additional feeder fixation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
8.2.4.4 External Power supply for Siplace component table . . . . . . . . . . . . . . . . . . . . . 13
8.2.4.5 Additional Communication unit for splice detection . . . . . . . . . . . . . . . . . . . . . . 14
8.3 Pneumatic tape cutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8.3.1 Structure and function of the pneumatic tape cutter . . . . . . . . . . . . . . . . . . . . . . . . . 15
8.3.2 Jumper setting on the control unit at the tape cutter . . . . . . . . . . . . . . . . . . . . . . . . . 17
8.3.3 Empty tape duct. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18