1 - 18 S tudent Guide SIPLACE HF/HF3 10 Sitest Edition 09/2005 18 T win head height: Calibrate Head heigh t mean to determine Z-Zero po int correction. 10 Fig. 10.2 - 8 T win head height Sequence: – move to zero pulse – …

100%1 / 596
1 - 17
Student Guide SIPLACE HF/HF3
Edition 09/2005 10 Sitest
17
Sequence segment offset top (I):
Fig. 10.2 - 6 Princple picture of a calibration tool in the camera in 0° (left); in 180°(right).
After Segment offset bottom (II) we calibrate with Segment offset top (I) for C&P DLM 2 seg-
ments :
the deviation in X- and Y-direction of the turning axis of the segments referring to the camera
center of comp. camera in µm.
The Measurement is done in 0° 180° respective 90° 270°(to prove the result 8 measurements
per segment).
The Segment offset values are saved in PIP_OFF.MA.
Graphic view of the results from segment offset:
Fig. 10.2 - 7 Graphical view segment I and II
Note:
For the segment offset I (top), the size of deviation shouldn‘t be larger than 600µm (450 µm) for
the segments and the deviation between the segments shouldn‘t be larger than +/- 150 µm.
The segment offset II (bottom) should not be larger than +/- 150µm. The deviation of the segments
should not larger than +/-150 µm.
Note:
The segment offset II (bottom), from the segment 1 is always 0 that is the reference value to the
other segments.
1 - 18
Student Guide SIPLACE HF/HF3
10 Sitest Edition 09/2005
18
Twin head height: Calibrate Head height mean to determine Z-Zero point correction. 10
Fig. 10.2 - 8 Twin head height
Sequence:
move to zero pulse
set the position counter to 0
move with 517 nozzle to the transport rail
measure actual position
subtract ‘Kopfhöhe’ head height from Ideal.ma (65500)
subtract theoretical nozzle length
is zero point correction Z-pos.act. -nozzle length -head height = 0-corr.
IC camera: 10
After measuring the head height of TWIN head (Z-axis zero point correction) the TWIN -IC
camera is calibrated.
The first measurement is the focus level of the stationary camera. The TWIN head determine
with Segment 1 the Z height for optimized focusing. (this height is the centering height for bot-
tom side of components.)
The Pixel size in µm of the camera is determined next. Saved as:/XU_Pixel / YU_Pixel/ of cam-
era 11(in 79000 nm).
The camera center of the TWIN- IC-camera refer to the zero point of the machine (X- / Y-
counter zero position).
A
B
1
5
4
3
2
1. Incremental scale on the Z-axis
2. Incremental encoder fixed
3. Top of the conveyor rail
4. Head height
5. Nozzle lenght
1 - 19
Student Guide SIPLACE HF/HF3
Edition 09/2005 10 Sitest
19
Saved are all this data and coordinates in: KAM_DAT.MA in Data bloc camera 11: (for gantry 2)
Kamera_Position_X / 1483500, Kamera_Position_Y/ 1370500, Kamera_Offset_Z/ 5000
Calibration data of IC camera saved in mapp_pkt.ma file.
Calibration IC camera position fiducial
FC camera: (Option) 10
After measuring the head height of TWIN head the TWIN -FC camera is calibrated.
The first measurement is the focus level of the stationary camera. The TWIN head determine
with Segment 1 the Z height for optimized focusing. (this height is the centering height for bot-
tom side of components.)
The Pixel size in µm of the camera is determined next. Saved as:/XU_Pixel / YU_Pixel/ of cam-
era 15(in 19600 nm).
The camera center of the TWIN- FC-camera refer to the zero point of the machine (X- / Y-
counter zero position).
Saved are all this data and coordinates in: KAM_DAT.MA in Data bloc camera 15: (for gantry 2)
Kamera_Position_X / Kamera_Position_Y/ Kamera_Offset_Z/
Calibration IC camera position fiducial
Twin head segment offset bottom at segment 1 and 2: 10
The segment offset determined the middle of the segment to the PCB camera. That means the
D axis, center of sleeve of the TWIN (IC) -placement head refer to the camera center of PCB-
camera. This measurement is only done in the lower position so the result is saved as an
offset "2" at the head.
The coordinates saved in PIP_OFF.MA at Data bloc /Pipetten-Offsets unten Kopf 2/ Pipetten-Off-
sets unten Segment 1(2) Offset_X /Offset_Y /
Nozzle changer (C&P head, Twin head): 10
Note: Precondition for calibrate the nozzle changer is to check or determine the zero point cor-
rection for the D - Axis Twinhead, the configuration of the nozzle changer and the fill level.
Each nozzle magazine has an fiducial which will recognize during the calibration procedure at
first.
After that, the machine recognize the two fiducial of the holder from the magazine on the left
and right side.
optional, calibrate the pick up height from the nozzle changer.
optional, calibrate the reject position from the nozzle changer, necessary to reject nozzle which
are defekt.
Calibrate closed vacuum: 10
This function measure onto the fixed conveyor rail with the nozzle 518 the closed vacuum values