SG_FSE_SiplaceHF_HF3_00193901-05_eng - 第534页
1 - 60 S tudent Guide SIPLACE HF/HF3 1 1 MTC 2 Edition 09/2005 60 Checking and setting the handle se nsors 11 NOTE The handle sensors each comprise a reflecting light barrier wh ich can detect the handle of the WTC or th…

1 - 59
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
59
11.3.4.3 Light barriers
WARNING
You may only check and calibrate the light barriers of the feed axis with the correct zero positions,
transfer positions and removal positions of the lifting and feed axes.
Fig. 11.3 - 22 Light barriers on the feed axes
Key
1 Handle sensor
2 WTC safety query
3 Crash light barriers
Tools and accessories 11
– Adjustment gauge, crash light barriers (03021679-01)
– 1 set of hexagon socket wrenches
Preparatory measures 11
➠ Move the feed axis into the zero position.
3
2
1

1 - 60
Student Guide SIPLACE HF/HF3
11 MTC 2 Edition 09/2005
60
Checking and setting the handle sensors 11
NOTE
The handle sensors each comprise a reflecting light barrier which can detect the handle of the
WTC or the side of the handle of the WTC XL. An LED indicates the switching status of the sensor.
Fig. 11.3 - 23 Checking and setting the handle sensors
Key
1 Reflecting light barriers of the handle sensors
2 Mounting plates with clamping screws
3LEDs
➠ Unscrew the clamping screws of the mounting plate.
➠ Move the mounting plate in the direction of the WTC until the reflecting light barrier responds
(the LED will change its status). Fix the plate in place there.
➠ Ensure that the status of the LED remains the same when you move the locked WTC. If
necessary, move the mounting plate a little further in the direction of the WTC.
➠ Firmly tighten the clamping screws.
3
2
1

1 - 61
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
61
11.3.4.4 Checking and setting the WTC safety queries
NOTE
The WTC safety queries each comprise a light barrier which is interrupted by the front edge of the
WTC or the WTC XL. Two LEDs indicate the switching status of the sensor.
NOTE
Make the settings for the feed axis of tower 1 first and then the feed axis of tower 2.
The light barrier holder in the middle accepts the light barriers for both axes but cannot be set
separately. When making settings, both the holder for the sender and the holder for the receiver
of the light barrier pairs must be moved.
Fig. 11.3 - 24 Checking and setting the WTC safety query
Key
1 Light barrier for the WTC safety query for tower 1
2 Light barrier for the WTC safety query for tower 2
3 Light barrier holder with clamping screws
➠ Unscrew the clamping screws on the middle holder and move it by the following fixed adjust-
ment amounts (see
Fig. 11.3 - 24Checking and setting the WTC safety query):
-Tower 1, left side = 3 mm
-Tower 1, right side = 4 mm
-Tower 2, left side = 4 mm
-Tower 2, right side = 5.5 mm
1
2
3
32,50
34
4
5,50
3
3