1 - 69 S tudent Guide SIPLACE HF/HF3 Edition 09/2005 1 1 MTC 2 69 1 1.3.6.3 Machine p arameters for tower 2 Machine p arameters for the lif ting axis on tower 2 11 Offset, zero po sition: -566.420 mm Position of operator…

100%1 / 596
1 - 68
Student Guide SIPLACE HF/HF3
11 MTC 2 Edition 09/2005
68
Travel parameters
Default speed, WTC: 50
Default acceleration, WTC: 50
Speed, axis command:50
Acceleration, axis command:50
Acceleration, lower threshold value: 1
Acceleration, upper threshold value: 50
Machine parameters, feed axis, tower 1 11
Position of WTC removal position, cassette 1: 0 mm
Position of WTC removal position, cassette 2: 0.180 mm
Position of WTC removal position, cassette 3: 0.220 mm
Position of WTC removal position, cassette 4: 0.230 mm
Position of WTC removal position, cassette 5: 0.320 mm
Offset, zero position: -11.350 mm
Component transfer position: 646.500 mm
Minimum position: -3.389 mm
Maximum position: 652.548 mm
Service position: 249.999 mm
Travel parameters
Default speed, moving WTC out: 150
Default speed, moving WTC in: 150
Default acceleration, WTC:100
Speed, axis command: 50
Acceleration, axis command: 50
Acceleration, lower threshold value: 1
Acceleration, upper threshold value: 150
1 - 69
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
69
11.3.6.3 Machine parameters for tower 2
Machine parameters for the lifting axis on tower 2 11
Offset, zero position: -566.420 mm
Position of operator removal position, cassette 1: 0 mm
Position of operator removal position, cassette 2: 143.400 mm
Position of operator removal position, cassette 3: 286.950 mm
Position of operator removal position, cassette 4: 430.600 mm
Position of WTC removal position, cassette 1: 23.800 mm
Position of WTC removal position, cassette 2: 167.800 mm
Position of WTC removal position, cassette 3: 311.350 mm
Position of WTC removal position, cassette 4: 454.650 mm
Minimum position: -3.939 mm
Maximum position: 573.509 mm
Service position: 165.000 mm
Travel parameters
Default speed, WTC:50
Default acceleration, WTC: 50
Speed, axis command: 50
Acceleration, axis command: 50
Acceleration, lower threshold value:1
Acceleration, upper threshold value: 50
Machine parameters, feed axis, tower 2 11
Position of WTC removal position, cassette 1: 0 mm
Position of WTC removal position, cassette 2: 0.100 mm
Position of WTC removal position, cassette 3: 0.100 mm
Position of WTC removal position, cassette 4: 0.50 mm
Offset, zero position: -6.350 mm
Component transfer position: 647.100 mm
Minimum position: -10.204 mm
Maximum position: 647.706 mm
Service position: 249.999 mm
1 - 70
Student Guide SIPLACE HF/HF3
11 MTC 2 Edition 09/2005
70
Travel parameters
Default speed, moving WTC out: 200
Default speed, moving WTC in: 200
Default acceleration, WTC: 100
Speed, axis command:50
Acceleration, axis command: 50
Acceleration, lower threshold value: 1
Acceleration, upper threshold value: 50
Description of the LED terminal strips X04 and X05
LED No. Name Not actuated Actuated
X04-1 Neutral position light barrier, lifting axis, tower 1 off on
X04-2 Limit switch, lifting axis, tower 1, max. position on off
X04-3 Limit switch, lifting axis, tower 1, min. position on off
X04-4 Proximity switch, toothed belt, tower 1 on off
X04-5 Neutral position light barrier, feed axis, tower 1 off on
X04-6 Limit switch, feed axis, tower 1, min. position on off
X04-7 Limit switch, feed axis, tower 1, max. position on off
X04-8 Crash light barrier for tower 1, low trays on off
X04-9 Crash light barrier for tower 1, high trays on off
X04-10 Crash light barrier for tower 1, very high trays on off
X04-11 Safety query "WTC in cassette", tower 1 on off
X04-12 Driver disengaged, tower 1 off on
X04-13 Driver engaged, tower 1 off on
X04-14 WTC interlock locked, tower 1 on off
X04-15 WTC interlock open, tower 1 on off
X04-16 WTC handle sensor, tower 1 off on
X04-17 Guide rail closed, tower 1 off on
X04-18 Disengage driver, tower 1 off on
X04-19 Engage driver, tower 1 off on
X04-20 Unlock WTC unlock device, tower 1 off on
+24 V Control voltage off on
-24 V Control voltage off on