11.4 Masterdrives
11.4.1 Operating the master drive with the parametrization unit (PMU)
The PMU parameterizing unit enables parameterization, operator control and visualization of the
converters and inverters directly on the unit itself.
Fig. 11.4 - 1 PMU parameterizing unit
With the toggle key, you can change over:
from the parameter number to the parameter index
from the parameter index to the parameter value
from the parameter value to the parameter number
If the parameter is not indexed, you can jump directly from the parameter number to the parameter
value.
Fig. 11.4 - 2 Toggle key of the PMU
1 - 76
Student Guide SIPLACE HF/HF3
11 MTC 2 Edition 09/2005
76
11.4.2 Important Parameter for trouble shooting
U / r = visualization parameters
P = parameters which can be changed
r004 = Output current inverter, converter
r006 = actually DC link voltage
r009 = Temperature motor
r069 = Software version Index 1 main unit
Index 2 Option unit slot A
11
Index 3 Option unit slot B 11
Index 4 Option unit slot C 11
U003 = Parameter set version:
for the Feed axis tower 1/2 software version
for the Lifting axis tower 1/2 software version
Note: On the MTC 2 are four different parameter sets, because the mechanical construction for
tower 1 and tower 2 is different and new parameter sets for new Hardware e.g. motor lifting axis
version 02.
So, please look always to new technical information in the DMS!
U501 = Machine data
P060 = Function parameter to choose actually menu.
Index 4:Unit configuration: Address
11
P095 = Motor list with standard motors
P096 =Function parameter motor
Define serial Interface: 11
P700 interface address of COM 1
P701 baud rate 8 is equal to 38400
1 - 77
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
77
11.4.3 Factory settings
Reset the Master drives to the define defaults
NOTE
When setting factory defaults, the axis concerned must not be subject to position control.
You must change 3 Parameters to define the defaults after this you can download the parameter
set for the axis.
1. Change Parameter P053 from 7 to 6 (This value is a Binary code 0111
0110).
2. Set Parameter P060 from 7 to 2.
3. Change Parameter P970 from 1 to 0. Parameter-Reset is started.
Check the serial interface and CAN Bus address after RESET: 11
1. Adjust the V24 (RS232) Interface.
Parameter P700 = 0
Parameter P701
Index 1= 8 (8 = Baud rate 38400).
2. Check the address for Can -Bus Parameter P918.
3. Download the Parameter set for the Axis with the Laptop.