SG_FSE_SiplaceHF_HF3_00193901-05_eng - 第567页

1 - 4 S tudent Guide SIPLACE HF/HF3 14 T est Equipm ent Edition 09/2005 4 14.2 T he SIPLACE Axis T ester fig.: 14.2 - 1 Axis tester - plan view j 240 x 128 pixel LCD display , black and white, backlit The menus appear on…

100%1 / 596
1 - 3
Student Guide SIPLACE HF/HF3
Edition 09/2005 14 Test Equipment
3
14 Test Equipment
14.1 Overview
I/O-Encoder (S15/S20/S23/F
3
/F
4
/F
5
) 00321960-01
Adapter Track signal tester Siplace S27 HM / F5 HM 00360395-01
Track signal tester Siplace S20/S23S25 HM / F
4
/ F
5
/ & S27 HM / F5 HM 00322510-01
Track signal tester (analog) Siplace HS 50 / HS 60 / HF / HF 3 00343785-01
Digital manometer for S20/S23S25 HM / F
4
/ F
5
00311487-01
Axis test box SIPLACE + with cable and adapter board (00303430-06)
SIPLACE AxisTester SAT 03002801-01
(Adapter for SAT testing AC 360 at WPC/SIPLACE S15/F3/G) 03002874-01
Belt tension meter TSM 00326015-01
RC-filter for OSCI fg=1.6kHz 02102858-01
Measuring adapter 14 poles / 34poles 02304826-01 / 02304827-01
Tweezers for compressed air hoses (in Service box) 00346929-01
Power supply 5 V Star mount at DLM1/2 00353277-01
Tab. 14.1 - 1 measuring Tools
Adjustment gauges set complete, C&P placement head
(with following contents) 00327005-01
Distance gauge 0.2 mm 00325445-01
Zero gauge star axis 00326164-01
Test pin 1.3mm old!
(replace this by a 1.0 mm Testpin or a 1.1 mm Drill from maintenance set.) 00326163-01
Test pin for DP-Encoder 1.4mm 00326160-01
Test pin for DP-Encoder 1.5mm 00326161-01
Test pin for DP-Encoder 1.6mm 00326162-01
Gauge for Z-axis stop 00331308-01
Z-End stop gauge placement star 03019865-01
calibration nozzle for zero point correction D axis TWIN head 03008862-02
Calibration jig VISION, Vers. III (for HF & SC/MC 505 machines) 03010565-01
Calibration jig VISION, Vers. II (for SC/MC 40X & 501/502/503 machines) 00316081-03
optional, additional measuring tools
Tab. 14.1 - 2 Adjustment Gauges and calibration tools
1 - 4
Student Guide SIPLACE HF/HF3
14 Test Equipment Edition 09/2005
4
14.2 The SIPLACE Axis Tester
fig.: 14.2 - 1 Axis tester - plan view
j 240 x 128 pixel LCD display, black and white, backlit
The menus appear on the LCD display and the recorded trigger, track and position deviation
signals are displayed graphically. All the relevant parameters, such as
- time base,
- measured times,
- amplitude scaling,
- signal level and
- cursor positions with the associated time differences
appear as alphanumeric information over the graphical representation of the measured curves.
k Dynamic function display for the BNC panel assignments on the LCD display
Mapping plate 520mm x 460mm 00325743-01
Mapping plate 520 x 215, (double transport) 00325698-01
Fine calibration set 00343710-01
Gauge for ’Ballrace’ 00333625-
Gauge for Z-Axis(jaw) 00335346-
Tab. 14.1 - 2 Adjustment Gauges and calibration tools
k
j
l
m
n
1 - 5
Student Guide SIPLACE HF/HF3
Edition 09/2005 14 Test Equipment
5
l Dynamic function display for the membrane key assignments on the LCD display
m Five membrane keys for menu control
n Green operating display LED
fig.: 14.2 - 2 Axis tester – bottom view
j Connection for ribbon cable
Connection on the axis tester: 37-pin sub-D connector
Connection on the axis controller:
37-pin sub-D connector for S-20/23/25/F4/F5 and HS-50 machines with A361 or A362 axis
controllers
25-pin sub-D connector for S-15/F3, G and wafflepack changer machines with A360 axis
controllers
An adapter is attached to the ribbon cable in order to connect the 25-pin axis controller.
The axis controller supplies the
+ 5 VDC ± 5 % and
± 15 VDC ± 5 %
operating voltages to the axis tester via the 37-pin ribbon cable.
k 9-pin sub-D connector for the CAN bus cable, e.g. for connecting CAN bus-controlled boards
in the placement machine (transmission speed 128 kBaud to 1 Mbaud, impedance 120 Ohm).
l 9-pin sub-D connector for the serial interface cable (V24), e.g. for connecting an external PC
(max. transmission speed 188 kBaud).
j
k
l
m