00198207-01_VB_BoardGateKeeper2.0_de_en - 第27页
Requirements Software Requirements SIPLACE BoardGateKeeper 2.0 27 3 3 R e q u ir e m e n t s Requirements 3.1 3 . 1 S o f t w a r e R e q u ir e m e n t s Software Requirements To run the BoardGateKeeper 2.0 system, you …
BoardGateKeeper Interfaces
26 SIPLACE BoardGateKeeper 2.0

Requirements
Software Requirements
SIPLACE BoardGateKeeper 2.0 27
3
3 Requirements
Requirements
3.1
3.1 Software Requirements
Software Requirements
To run the BoardGateKeeper 2.0 system, you need to install the following software:
▪ SIPLACE Pro 13.1 (recommended), 13.0 (compatible)
▪ OIB 4.3 Core
▪ Optional: OIB LineControl adapter (for integration of multiple, line-specific MES systems)
3.2
3.2 Time Sync
Time Sync
To ensure that you can trace board production data properly at a later date, it is important that all systems
involved have synchronized time keeping. The individual times in the various systems can be automat-
ically synchronized with the SIPLACE Time Sync tool.
SIPLACE Time Sync is a client server application, which helps to synchronize the time at all SIPLACE
machines and all line computers (client) via the SIPLACE Pro computer or a central time server (server).
Time Sync is installed and configured on one particular computer as a time server and on one or more
other computers as a client.
The SIPLACE Pro computer has proven to be an ideal time server.
NOTICE
Time Sync
After installing the Time Sync server and Time Sync client, check the settings for "Time Sync"
and correct the times where necessary, at the Time Sync client.
The current Time Sync software and software instructions can be found on a Support Media
2.3, supplied with each software product.
Requirements
Time Sync
28 SIPLACE BoardGateKeeper 2.0