TECHNICAL REFERENCE APPENDIX PREVENTIVE MAINTENANCE 3.64 Appendix to Micron Technical Manuals Chapter Issue 1 June 15 Month January Maintenance Procedure W A RNING BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORK I…

100%1 / 165
TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.63
Monthly
Maintenance
Each month the following tables are filled in prior to carrying out any equipment
checks. Run ten cycles prior to making the thirty test measurements.
SPC Alignment
Check
Follow details in the Accuracy Check section previously described in this
chapter. Record details for each visit.
Machine Cycle
Count
Record the machine cycle count for each visit.
Visit Pre X Pre Y Pre Theta Post X Post Y Post Theta Front Sqy Rear Sqy
1
2
3
4 100 Cycles 100 Cycles 100 Cycles 100 Cycles 100 Cycles 100 Cycles 100 Cycles 100 Cycles
5
6
7
8
9
10
11
12
Visit Insert the Cycle Count No. of cycles between visits
1
2-
3-
4-
5-
6-
7-
8-
9-
10 -
11 -
12 -
TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
3.64 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
Month January Maintenance Procedure
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
HARMFUL SUBSTANCES. CLEANING WIPES AND CLEANING SOLUTIONS MAY
CONTAIN SUBSTANCES HAZARDOUS TO HEALTH. OBSERVE ALL
MANUFACTURERS’ HEALTH AND SAFETY GUIDELINES. ALWAYS WEAR
APPROVED PROTECTIVE CLOTHING WHEN CLEANING THE MACHINE.
SPC Alignment
Check and Machine
Cycle Count
Fill out details: SPC Alignment Check and Machine Cycle Count at the start of
this section.
Software
Monthly Maintenance
SEMI Level Software Check Record Tick
Check the date and time settings.
Check the software loaded and options.
Check the software version is the latest issue.
SEMI 2
SEMI Level View Event Log Tick
Check for initialisation errors.
Check for screen position errors (31210, 31211, 31212).
Check for camera errors (31207, 31208).
SEMI 2
SEMI Level Under Screen Cleaner (USC) Tick
Check the condition of the squeegee blades (Blue).
NOTE
ASM recommend squeegee blades are replaced every six months.
Check the screen cleaner height.
Check the condition of all hoses and connections.
SEMI 1
TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.65
Check that the paper feed mechanism operates correctly.
Check that the cleaner mechanism raises and lowers smoothly.
Check that the solvent dispenses and it is at a suitable pressure.
Check that solvent dispenses evenly across the paper or cassette.
Check the correct operation of the vacuum filtration unit.
Perform a USC cycle and confirm correct operation.
SEMI Level Under Screen Cleaner (USC) Tick
SEMI 2
SEMI Level Environmental Control Module (if fitted) Tick
Inspect the air filters clean/replace (as detailed in the equipment manual).
Check for leakage in the system.
Check the system holds the temperature (as described in the equipment manual).
SEMI 1
SEMI 2
SEMI Level General Maintenance Tick
Check the printhead front cover glass for scratches, scuffs, dimples, blisters, bubbles
or chips on the glass and the glass edge. If any damage is found, contact your local
CSG office (reference KB1477).
Check the condition of the board clamps.
Clean the table top of paste and debris, apply a wipe of light oil.
Clean the round transport rails of paste and debris.
Inspect the air filters and clean/recommend replacement.
Cycle the board clamps ensure that clamping and release is smooth.
Cycle the Test 265test 1 board on the transport rails ensure smooth operation.
SEMI 1
SEMI 2