Horizon APiX Appendix Manual-low res - 第127页
TECHNICAL REFERENCE APPENDIX PREVENTIVE MAINTENANCE 3.90 Appendix to Micron Technical Manuals Chapter Issue 1 June 15 Monthly Hardware Check SEMI Level Machine Safety Tick The Factory supply must be isolated an d locked …

TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.89
Check that the paper feed mechanism operates correctly.
Check that the cleaner mechanism raises and lowers smoothly.
Check that the solvent dispenses and it is at a suitable pressure.
Check that solvent dispenses evenly across the paper or cassette.
Check the correct operation of the vacuum filtration unit.
Perform a USC cycle and confirm correct operation.
SEMI Level Under Screen Cleaner (USC) Tick
SEMI 2
SEMI Level Environmental Control Module (if fitted) Tick
Inspect the air filters clean/replace (as detailed in the equipment manual).
Check for leakage in the system.
Check the system holds the temperature (as described in the equipment manual).
SEMI 1
SEMI 2
SEMI Level General Maintenance Tick
Check the condition of the board clamps.
Clean the table top of paste and debris, apply a wipe of light oil.
Clean the round transport rails of paste and debris.
Inspect the air filters and clean/recommend replacement.
Cycle the board clamps ensure that clamping and release is smooth.
Cycle the Test 265test 1 board on the transport rails ensure smooth operation.
SEMI 1
SEMI 2

TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
3.90 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
Monthly Hardware Check
SEMI Level Machine Safety Tick
The Factory supply must be isolated and locked out before an examination of the
mains input lead can be carried out.
Examine the condition of the mains input lead.
Check all earth leads and bonding points are connected.
Check operation of the cover interlock.
Check operation of the Emergency Machine Off button.
Toggle all beacon lights.
SEMI 1
SEMI 2
SEMI Level Pneumatics Tick
Check air pressure switch is set to 3 bar.
Check the air inlet regulator is set to 4.5 bar.
Check pipes for air leaks.
Check and empty the air line water trap.
SEMI 1
SEMI Level Screen Change Tick
Remove and clean the auto drip tray.
Fully extend the auto drip tray telescopic plungers and clean.
Clean the screen stop actuator arm lever.
Clean the screen at stop sensor.
Refit the auto drip tray and check operation of the screen change mechanism.
SEMI 1
SEMI 2

TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.91
SEMI Level Chase Tick
Inspect the condition of wiring/pneumatic connections.
Clean and lubricate with light oil, the omni track bearings and the underside of the track
plates.
Clean the left and right screen at centre optos.
Clean the stencil guide strips of debris/paste.
Remove the ASM pneumatic cylinder covers.
Ensure ASM cable assembly is seated correctly around all pulleys.
Loosen cable retainer bracket securing screws. Adjust position of bracket to eliminate
any cable slack.
Ensure all screen clamps are at their home position. Tighten retainer bracket securing
screws.
Refit ASM pneumatic cylinder covers.
Check operation of the chase clamps.
Check operation of the ASM.
SEMI 1
SEMI 2
Estimated time required for Monthly tasks 4.0 hours
Summary/Remarks
Signed: Date: