TECHNICAL REFERENCE APPENDIX PREVENTIVE MAINTENANCE 3.102 Appendix to Micron Technical Manuals Chapter Issue 1 June 15 Estimated time req uired for Monthly tasks 4.0 h ours Summary/Remarks Signed: Date:

100%1 / 165
TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.101
SEMI Level M37 Power Supply Enclosure Tick
Inspect wiring and connections.
Clean area around air inlet.
SEMI 1
SEMI Level M39 Emergency Machine Off Enclosure Tick
Inspect wiring and connections.
SEMI 1
SEMI Level PC Enclosure Tick
Inspect wiring and connections.
SEMI 1
TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
3.102 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
Estimated time required for Monthly tasks 4.0 hours
Summary/Remarks
Signed: Date:
TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.103
Month November Maintenance Procedure
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
HARMFUL SUBSTANCES. CLEANING WIPES AND CLEANING SOLUTIONS MAY
CONTAIN SUBSTANCES HAZARDOUS TO HEALTH. OBSERVE ALL
MANUFACTURERS’ HEALTH AND SAFETY GUIDELINES. ALWAYS WEAR
APPROVED PROTECTIVE CLOTHING WHEN CLEANING THE MACHINE.
SPC Alignment
Check and Machine
Cycle Count
Fill out details: SPC Alignment Check and Machine Cycle Count at the start of
this section.
Software
Monthly Maintenance
SEMI Level Software Check Record Tick
Check the date and time settings.
Check the software loaded and options.
Check the software version is the latest issue.
SEMI 2
SEMI Level View Event Log Tick
Check for initialisation errors.
Check for screen position errors (31210, 31211, 31212).
Check for camera errors (31207, 31208).
SEMI 2
SEMI Level Under Screen Cleaner (USC) Tick
Check the condition of the squeegee blades (Blue).
NOTE
ASM recommend squeegee blades are replaced every six months.
Check the screen cleaner height.
Check the condition of all hoses and connections.
SEMI 1