Speed (Single-Sided) DLM-RV12 - Option 1 Installation Procedures 18 Assembly Instructions E by SIPLACE ► Connect the diameter 6 mm tube "T ube Nozzle Changer LOC1" [03102 149 - xx] to port 3 of the air service …

100%1 / 34
Speed (Single-Sided) DLM-RV12 - Option 1
Installation Procedures
Assembly Instructions E by SIPLACE 17
Connect the cable [03102710
-
xx] to the cable of the nozzle changer "NC single row for DLM4 RV6/
12, C&P14 P" [03106322
-
xx].
Mount the nozzle changer onto the shim covers on both ends and secure it with four M5x14 cap
screws.
Assemble the active nozzle magazines.
Remove the yellow covers shown.
Speed (Single-Sided) DLM-RV12 - Option 1
Installation Procedures
18 Assembly Instructions E by SIPLACE
Connect the diameter 6 mm tube "Tube Nozzle Changer LOC1" [03102149
-
xx] to port 3 of the air
service unit located in location 2.
Port 3 is the port shown in yellow in the below picture.
Route the tube [03102149
-
xx] from the air service unit to the indicated area in location 1.
Connect the tube [03102149
-
xx] to the tube of the nozzle changer via the provided "6-4 reducer fit
-
ting" [00386293
-
xx].
Refit all the removed covers.
Speed (Single-Sided) DLM-RV12 - Option 2
Installation Procedures
Assembly Instructions E by SIPLACE 19
3
3 Speed (Single-Sided) DLM-RV12 - Option 2
Speed (Single-Sided) DLM-RV12 - Option 2
A "SPEED (Single-Sided) option 1" configuration can be enhanced with "SPEED Option 2", which con
-
sists of an additional "NC Speed kit reject bin small" [03113189
-
xx] and a "Module sensor reject box
LOC2" [03102729
-
xx] located at location 2.
3.1
3.1 Installation Procedures
Installation Procedures
Mount the "NC mounting bracket Speed left" [03108126
-
xx] (1) onto the machine frame using two
5x12 dowel pins and two M5x30 cap screws.
STANDARD SPEED (SS) RV12 SPEED (SS) RV12 OPTION 2
1 Location 1 2 Location 2