Sensor 4 Error
4 Holder Motor Error
4.1 Sensor 5 or 6, ON/OFF error: Incorrect detection height adjustment.
4.2 Motor Error: Motor or Motor Driver malfunction.
Up-Holder Motor Error
5 PC & PLC Communication Error: The candidate board has been locked and the PC notified
to commence testing. No action taken within 10 seconds of the notification.
5.1 PC & PLC communication link malfunction.
5.2 PC program not being executed or malfunctioning.
PC & PLC Communication Error
6 Speed Reduction Error: When the loading speed is too fast or Sensor 1 and Sensor 2 are
located too closely together, speed reduction may not occur in time so this measure is
triggered to prevent board from falling off.
7 Board Test Fail: When the test results in a Fail, the PC will send a FAIL signal. A confirmation
from the PC is required before it can return to the systems operational display.
22
1.4 Human Machine Interface Program Replacement
l Before replacing the PLC and HCI program the original files must be purged. The steps are
as follows:
Step 1 : At the Start Test display press down on four corners of the HCI.
Step 2 : At the display, press Setting.
Step 3 : Press Memory.
Step 4 : Press [SRAM] and [FROM] to purge the Memory.
u Human Machine Interface Program Update Process is as follows:
Step 1: First connect the PLC-PC data cable properly, with the PS2 connector connected to
the rear of the PCI, and the RS232 connected to Main PC COM1.
Step 2: Open the Program Files GTWIN (as shown in the figure below)
System Menu ESC
System Ver 2.02
Setting
Test
System Menu ESC
Clock
Contrast
Memory
TOOL Port
COM. Port
System Menu ESC
SRAM
FROM
23
Step 3: Enter the GTWIN software program and as shown in the figure below, select Read
from GT (Read HCI data).
Step 4: After loading (this takes some time, please wait patiently), click on the File and select
Save so as to make a backup of the original files as shown in the picture below.