CM602all_EJM8AESM_Service Manual - 第141页

Maintenance Adjustment Main Body Beam Remarks Item Adjust the lamp value. To check the jig: LAMP1=6 LAMP2=6 To check a glass-epoxy board: LAMP1=100 LAMP2= 10 Move the head assembly to the jig manually. Loosen the head ca…

100%1 / 1093
Maintenance Adjustment Main Body Beam
Remarks
Remove the feeder cover.
Phillips screwdriver #2
Screw M4 2 pcs.
Adjust the conveyor width.
Enter 50 into the [W] box.
Remove the fixed and the movable Z
Place the
j
i
g
on the conve
y
or.
clamp plates.
Head camera focusing jig
Allen key 3 mm
Screw M4 4 pcs.
"Recognition unit maintenance For adjustment" screen
Key disk
Refer to "Key Switch/Key
Disk Receipt Confirmation
and Safety Precautions."
3
4
1
Item
2
ON
EJM8A-E-SMA040102-A01-00
Page 4-1-2-2
Maintenance Adjustment Main Body Beam
Remarks
Item
Adjust the lamp value.
To check the jig:
   LAMP1=6
        LAMP2=6
To check a glass-epoxy board:
  LAMP1=100
        LAMP2= 10
Move the head assembly to the jig manually.
Loosen the head camera holding screws.
How to focus the camera:
Move the camera up and down until one
of the two holes on the camera focusing
jig is displayed on the screen as clearly
as the other hole.
Allen key 3 mm
Tighten the head camera holding screws.
When positioning the head camera unit,
make the LED light parallel with the X
and the Y axes.
Allen key 3 mm
5
6
7
8
EJM8A-E-SMA040102-A01-00
Page 4-1-2-3
Maintenance Adjustment Main Body Beam
Remarks
Item
Remove the
j
i
g
from the conve
y
or.
Move the head assembly to the steel rails.
Loosen the theta holding set screws.
Be careful not to let small brass bushings
fall off the screw holes.
Allen key 1.5 mm
Looking at the camera from above, Looking at the camera from above
turn the head camera unit clockwise. turn the head camera unit counterclockwise.
within +/- 0.2°
9
10
11
12
NG OK NG
No
screw
Loosen
EJM8A-E-SMA040102-A01-00
Page 4-1-2-4