CM602all_EJM8AESM_Service Manual - 第181页

Kgs. R emova l Disassembl y A ssem bly A d j ustment Teaching Total Time W e i g ht o f Part min. 30 min. 30 m i n . min. ・ Tools ・ Jigs None None Maintenance Adjustment Main Body Beam ・ This section describes the proced…

100%1 / 1093
Maintenance Adjustment Main Body Beam
Remarks
Item
Adjust the clearance, hammering the fixed blade block.
Hammer
Allen key 4 mm
Screw M5 9 pcs.
Check the clearance.
Specification:
0 to 0.02 mm
Feeler gauge
Tighten the screws holding the fixed balde block.
Allen key 4 mm
Screw M5 12 pcs.
Put back the cutter unit.
See "Cutter Unit Replacement." Section 5-9-4
5
6
7
8
Lowering the fixed cutter blade slowly,.
adjust the gap of the movable and the
fixed cutter blades.
If lower excessively, return to Step 4
and raise the cutter blade.
=Jig
0 to 0.02 mm
Fixed cutter blade
Movabel cutter blade
=Jig
Once adjustment
is finished, tighten.
EJM8A-E-SMA040112-A01-00
Page 4-1-12-3
Kgs.
R
emova
l
Disassembl
y
A
ssem
bly
A
d
j
ustment
Teaching
Total Time
W
e
i
g
ht
o
f
Part
min. 30 min.
30
m
i
n
.
min.
Tools
Jigs
None
None
Maintenance Adjustment Main Body Beam
This section describes the procedures for adjusting the air pressure.
4-1-13 Air Pressure Adjustment
Caution
Dange
r
Warning
EJM8A-E-SMA040113-A01-00
Page 4-1-13-1
Main Air Pressure
S
p
ecifications:
0.49M
p
a to 0.78M
p
a
1
Bulk Feeder Su
pp
l
y
Ai
r
Pressure:
S
p
ecifications:
0.29M
p
a to 0.34M
p
a
2
A
ir Blow Pressure
S
p
ecifications:
0.07M
p
a±0.005M
p
a
3
If the value is outside the s
p
ecifications
,
Vacuum
p
ressure
check that: S
p
ecification:
1. the vacuum tube is NOT broken. -85M
p
a to -95M
p
a
2. the head vacuum sensor is fitted in
p
osition.
4
3. the
j
oint is connected
p
ro
p
erl
y
.
4. the vacuum
p
um
p
works
p
ro
p
erl
y
.
Main Air Pressure
Maintenance Adjustment Main Body Beam
Item Remark
Vacuum Pressure
Bulk Feeder Supply Air Pressure
Air Blow Pressure
CloseOpen
Close
Open
Close
Open
EJM8A-E-SMA040113-A01-00