CM602all_EJM8AESM_Service Manual - 第205页
Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles) Remarks Item Press [Unlock] and [Height org tch] simultaneously. The head camera moves to the heat calibration mark of that stage and measures the height of…

Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Press [Zaxis origin offset].
When using eight
nozzles, follow Steps 1 to
8.
Select the stage to be taught.
When selecting the
stage, check that [Gang]
is selected.
Press [Unlock] and [Return to origin] simultaneously.
The selected stage returns to the origin.
Press [Unlock] and [Jig setting] simultaneously.
The head moves to the nozzle setting
position (over the NG box).
Set Nozzle 130 on each
nozzle position.
2
3
4
Item
1
EJM8A-E-SMA040203-A01-00
Page 4-2-3-2

Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Item
Press [Unlock] and [Height org tch] simultaneously.
The head camera moves to the heat
calibration mark of that stage and
measures the height of each nozzle.
After the height of Nozzle 8 is measured,
the head stops moving down.
Press [Unlock] and [Jig remove] simultaneously.
The head moves to the nozzle setting
position.
Remove Nozzle 130 from
each nozzle position.
Press the "Return" key.
To save the machine
parameter, press the
[Return] key.
Press [Unlock] and [Run] simultaneously.
The X- and the Y- axes return to the
origin.
5
6
7
8
EJM8A-E-SMA040203-A01-00
Page 4-2-3-3

Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Item
Select the stage to be taught.
When using one nozzle, follow Steps 9
to 16.
Press [Nozzle].
If using one nozzle, teach
each nozzle separately.
Press [Unlock] and [Return to origin] simultaneously.
The selected stage returns to the origin.
Press [Unlock] and [Jig setting] simultaneously.
Set Nozzle 130 on the
nozzle position displayed
on the screen.
9
12
11
10
EJM8A-E-SMA040203-A01-00
Page 4-2-3-4