CM602all_EJM8AESM_Service Manual - 第240页

Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles) Remarks Press [Pickup position]. Select the stage to be taught. Check that: "XY" and "Z" are selected (highlighted). Check that "Ch…

100%1 / 1093
Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
This section describes the procedures for teaching the pickup position.
Tools
None
Jig
FM-1043
Nozzle Height Teaching
Jig
Nozzle 120 or 130
4-2-8       Pickup Position
 
        Install the feeder change cart.
Assembly
A
d
j
ustment
min.
Teaching
5min.
Total Time Weight of
Part
Removal
Disassembl
y
min.
5min.
kgs
Caution
Dange
r
Warning
EJM8A-E-SMA040208-A01-00
Page 4-2-8-1
Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Press [Pickup position].
Select the stage to be taught.
Check that:
"XY" and "Z" are selected
(highlighted).
Check that "Check Posi L
table" is selected.
If "Check Posi R table" is
selected, press that key to
change "R" to "L."
Press [Unlock] and [Jig setting] simultaneously.
Place the jig at Position 2
of the feeder table of the
selected stage.
Fit Nozzle 120 or 130 onto
Nozzle position 3.
Press [Unlock] and [Pick pos teach] simultaneously.
The head moves over to the jig.
The head camera recognizes the hole on
the jig so that X and Y of the pickup
position are recognized and corrected.
Nozzle 3 descends to the jig so that Z of
the pickup position is determined.
3
4
1
Item
2
EJM8A-E-SMA040208-A01-00
Page 4-2-8-2
Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Item
Press [Teach Posi L table].
Change "Teach Posi L table" to "Teach
Posi R table."
If "Teach Posi L table" is
selected, press that key to
change "L" to "R."
Press [Unlock] and [Jig setting] simultaneously.
Place the jig at Position
27 of the feeder table of
the selected stage.
Press [Unlock] and [Pick pos teach] simultaneously.
The head moves over to the jig.
The head camera recognizes the hole on
the jig so that X and Y of the pickup
position are recognized and corrected.
Nozzle 3 descends to the jig so that Z of
the pickup position is determined.
Press [Unlock] and [Jig remove] simultaneously.
The head moves to the nozzle set
position (over the NG box).
Remove the jig and the
nozzle.
5
6
7
8
EJM8A-E-SMA040208-A01-00
Page 4-2-8-3