CM602all_EJM8AESM_Service Manual - 第256页
Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles) This section describes the procedures for entering the offset for the Z-axis origin. Tools None Jig Nozzle 1003 1 pc or 3 pcs. 4-3-3 Z-axis Origin Offset Cl…

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Item
Press [Unlock] and [Xyaxis org offset mgf teach] simultaneously.
The head camera recognizes the mark.
The offset for the magnification of the camera
is entered.
Check data after teaching.
Offsets are entered automatically into the screen below:
Offset range:
Magnifying power
PCB recog camera:
X: 0.0096 to 0.0104
Y: 0.0096 to 0.0104
Origin offset:
X: -2.0 mm to +2.0 mm
Y: -2.0 mm to +2.0 mm
5
6
7
EJM8A-E-SMA040302-A01-00
Page 4-3-2-3

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
This section describes the procedures for entering the offset for the Z-axis origin.
Tools
None
Jig
Nozzle 1003
1 pc or 3 pcs.
4-3-3 Z-axis Origin Offset
Clean the upper surface of the thermal correction mark beforehand.
Remove the feeder cover.
Caution
Dange
r
Warning
Assembly
A
d
j
ustment
min.
Teaching
5min.
Total Time Weight of
Part
Removal
Disassembl
y
min.
5min.
kgs
EJM8A-E-SMA040303-A01-00
Page4-3-3-1

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Press [Zaxis origin offset].
When using three
nozzles, follow Steps 1 to
8.
Select the stage to be taught.
When selecting the stage,
check that [Gang] is
selected.
Press [Unlock] and [Return to origin] simultaneously.
The selected stage returns to the origin.
Press [Unlock] and [Jig setting] simultaneously.
The head moves to the nozzle setting
position (over the NG box).
Set Nozzle 1003 on all
nozzle positions.
3
4
1
Item
2
EJM8A-E-SMA040303-A01-00
Page4-3-3-2