CM602all_EJM8AESM_Service Manual - 第292页
Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles) Remarks Item Press [Teach Posi L table]. Change to [Teach Posi R table]. If the left table is selected, press [Teach Posi L table] in order to select the ri…

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Press [Pickup position].
Select the stage to be taught.
Check that [XY] and [Z]
are highlighted.
Check that the left table is
selected.
If the right table is
selected, press [Teach
Posi R table] in order to
select the left table.
Press [Unlock] and [Jig setting] simultaneously.
Place the jig on Feeder
Table Position 2.
Place Nozzle 1003 onto
Head 3.
Press [Unlock] and [Jig setting] simultaneously.
The head moves to the jig. → The holes
of the jig are recognized. (X・Y)→ Head 1
descends. (Z)
3
4
1
Item
2
EJM8A-E-SMA040308-A01-00
Page4-3-8-2

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Item
Press [Teach Posi L table].
Change to [Teach Posi R table]. If the left table is selected,
press [Teach Posi L table]
in order to select the right
table.
Press [Unlock] and [Jig setting] simultaneously.
Place the jig on the
Feeder Table Position 27
of the selected stage.
Press [Unlock] and [Pick pos teach] simultaneously.
The head moves to the jig. → The holes
of the jig are recognized. (X・Y)→ Head 1
descends. (Z)
Press [Unlock] and [Jig remove] simultaneously.
The head moves to the nozzle setting
position (over NG box).
Remove the jig and the
nozzle.
5
6
7
8
EJM8A-E-SMA040308-A01-00
Page4-3-8-3

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Item
Press the "Return" key.
To save the machine
parameters, press the
"Return" key.
Press [Unlock] and [Run] simultaneously.
The axes for the selected stage move to
the origin.
Offsets are entered into the screen below:
Offset range:
X=±1.0㎜
Y=±1.0㎜
Z=±1.0㎜
9
10
11
EJM8A-E-SMA040308-A01-00
Page4-3-8-4