CM602all_EJM8AESM_Service Manual - 第311页

Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles) Remarks Item Offsets are entered into the screen below: Offset range: X: -1.0 mm to 1.0 mm Y: -1.0 mm to 1.0 mm Z: -1.0 mm to 1.0 mm 9 EJM8A-E-SMA040311-A01-…

100%1 / 1093
Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles)
Remarks
Item
Press [Unlock] and [XY teach] simultaneously.
Starting from the point at which the Z
teaching is finished, X and Y are
measured automatically.
Press [Unlock] and [Jig remove] simultaneously.
Remove the jig from
Head 3.
Press the "Return" key.
Press [Unlock] and [Run] simultaneously.
The selected head returns to the origin.
5
6
7
8
EJM8A-E-SMA040311-A01-00
Page 4-3-11-3
Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles)
Remarks
Item
Offsets are entered into the screen below:
Offset range:
X: -1.0 mm to 1.0 mm
Y: -1.0 mm to 1.0 mm
Z: -1.0 mm to 1.0 mm
9
EJM8A-E-SMA040311-A01-00
Page 4-3-11-4
Tools
Jig
FM-1136
Light Intensity Teaching
Jig
None
4-3-12 Light Intensity
Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
This section describes the procedures for specifying light amount.
Weight of
Par
t
min. min.
Removal
Disassembl
y
A
ssembl
y
A
d
j
ustment
Teaching Total Time
Kgs
.
15 min.
15
min
.
Caution
Danger
Warning
EJM8A-E-SMA040312-A01-00
Page 4-3-12-1