Machinery Part Replacement Remarks Transfer Head Assembly (8-nozzle type) Item Remove the LED connector. Phillips screwdriver #1 Connector screw 2 pcs. Remove the cable holding bracket. Allen key 3 mm Screw M4 1 pc. Remo…

100%1 / 1093
Machinery Part Replacement
Remarks
Switch off the main power and air supply.
From 0.49MPa
to 0.55MPa
Remove the head assembly.
1-000279
Refer to "Transfer Head Assembly." Section 5-3-1
Remove the theta motor connectors. Cut the cable ties.
When removing the cables, be careful of
the cabling on the rear side.
Cut the cable ties. Remove the air tube.
Both front and rear sides. Nipper
Transfer Head Assembly (8-nozzle type)
1
3
4
Item
2
1
2
EJM8A-E-SMA050313-A01-00
Page 5-3-13-2
Machinery Part Replacement
Remarks
Transfer Head Assembly (8-nozzle type)
Item
Remove the LED connector.
Phillips screwdriver #1
Connector screw 2 pcs.
Remove the cable holding bracket.
Allen key 3 mm
Screw M4 1 pc.
Remove the valve and the vacuum sensor connectors.
Cut the cable ties. Rear side
5
6
8
7
CN1
CN2
CN3 CN4
CN5
CN12
CN10CN9
CN7
CN6
MC14CX
The same boards are installed at
the front and the rear sides
of the head assembly
EJM8A-E-SMA050313-A01-00
Page 5-3-13-3
Machinery Part Replacement
Remarks
Transfer Head Assembly (8-nozzle type)
Item
Remove the vacuum tubes and the valve connectors.
Both front and rear sides.
Remove the valves. (front and rear sides)
Both front and rear sides. Phillips screwdriver #1
Valve holding screw
16 pcs.
Remove the vacuum sensor.
Both front and rear sides. Allen key 2.5 mm
Screw M3 8 pcs.
Insert the plate and move down the shaft 20 mm or more.
Spacer 5 mm or thicker
11
12
9
10
EJM8A-E-SMA050313-A01-00
Page 5-3-13-4