CM602all_EJM8AESM_Service Manual - 第548页

Machinery Part Replacement Remarks Head Camera Unit Item Replace the camera. Take care with the orientation of the camera unit. (Check the connector position.) Lightly tighten the screws not to let the camera unit fall. …

100%1 / 1093
Machinery Part Replacement
Remarks
Switch off the power.
Remove the head cover.
2
Phillips screwdriver #1
Phillips screwdriver #2
Screw M3 8 pcs.
Screw M4 4 pcs.
Remove the connector.
Phillips screwdriver #1
Connector screws
Be careful not to let the camera unit fall.
Allen key 3 mm
Screw M4 4 pcs.
Remove the camera holding screws, holding the camera unit.
4
3
Head Camera Unit
1
Item
EJM8A-E-SMA050601-A01-00
Page 5-6-1-2
Machinery Part Replacement
Remarks
Head Camera Unit
Item
Replace the camera.
Take care with the orientation of the
camera unit. (Check the connector
position.)
Lightly tighten the screws not to let the camera unit fall.
Connect the connector.
Phillips screwdriver #1
Connector screws
Switch on the main power.
7
8
6
5
EJM8A-E-SMA050601-A01-00
Page 5-6-1-3
Machinery Part Replacement
Remarks
Head Camera Unit
Item
Adjust the camera.
Refer to "Head Camera Adjustment ---
Focus and Theta."
Section 4-1-2
9
EJM8A-E-SMA050601-A01-00
Page 5-6-1-4