Machinery Part Replacement
This section describes the procedures for removing the θ unit.
Tools
Phillips screwdriver #1
Allen key 2.5 mm
Allen key 3 mm
Allen key 4 mm
Nipper
Jig
None
12-Nozzle Head Unit
  5-10-8     θ Unit Removal
Caution
Dange
r
Warning
EJM8A-E-SMA051008-A01-00
Page 5-10-8-1
Machinery Part Replacement
Remark
Turn off the power and air supply.
0.49MPa to
0.55MPa
Remove the head.
See "12-Nozzle-Head-Unit
Replacement."
Section 5-10-1
Remove the front and top covers.
Phillips screwdriver #2
M4 truss screw 10 pcs.
Disconnect the
θ-motor connector. Cut off the cable tie.
Nipper
12-Nozzle Head Unit
Item
2
1
3
4
1
2
EJM8A-E-SMA051008-A01-00
Page 5-10-8-2
Machinery Part Replacement
Remark
12-Nozzle Head Unit
Item
Cut off the cable ties.
When removing the tube, put a mark on
the tubes so that they can put back in the
same place.
Nipper
Magic marker
Remove the cable and tube holding bracket.
Allen key
M3 x 6L 3 pcs.
Remove the tube.
Magic marker
Remove the vacuum-sensor connector.
Cut off the cable tie.
Nipper
5
6
8
7
Put a mark
here.
<Left side>
Front
EJM8A-E-SMA051008-A01-00