CM602all_EJM8AESM_Service Manual - 第673页

Machinery Part Replacement ・ Tools None ・ Jig Nozzle 130S: 1 pc or 8 pcs. 12-Nozzle Head Teaching 5-11-3 Z-axis Origin Offset Clean the upper surface of the thermal correction pole beforehand. Remove the feeder cover. Th…

100%1 / 1093
Machinery Part Replacement
Remarks
Item
12-Nozzle Head Teaching
Press [Unlock] and [Xyaxis org offset mgf teach] simultaneously.
The head camera recognizes the mark.
The offset for the magnification of the
camera is entered.
Press [Unlock] and [Run] simultaneously.
Offset range:
Board recognition
camera:
X mag.: 0.0096 to 0.0104
Y mag.: 0.0096 to 0.0104
Origin offset:
X: -2.0 mm to +2.0 mm
Y: -2.0 mm to +2.0 mm
5
6
7
Offsets are entered automatically into the screen below:
EJM8A-E-SMA051102-A01-00
Page 5-11-2-3
Machinery Part Replacement
Tools
None
Jig
Nozzle 130S:
1 pc or 8 pcs.
12-Nozzle Head Teaching
5-11-3 Z-axis Origin Offset
Clean the upper surface of the thermal correction pole beforehand.
Remove the feeder cover.
This section describes the procedures for setting the offset for the Z-axis origin.
Caution
Dange
r
Warning
EJM8A-E-SMA051103-A01-00
Page5-11-3-1
Machinery Part Replacement
Remarks
Press [Zaxis origin offset].
Select the stage to teach.
Select [Gang].
Press [Return to origin].
12-Nozzle Head Teaching
Item
1
2
3
4
When NOT selecting [Gang]:
Select the head number.
3-1 Press [Each head].
Pressing [Each head] highlights [Head No.] below.
3-2 Press [Head No.].
Pressing [Head No.] changes the head
numbers from1 to 12 one by one.
EJM8A-E-SMA051103-A01-00
Page5-11-3-2