CM602all_EJM8AESM_Service Manual - 第696页

This section describes the procedures for determining the light intensity. Tools 5-11-9 Light Intensity Machinery Part Replacement 12-Nozzle Head Teaching Jig FM-0934 Light-intensity-teaching jig None Shadow-light-intens…

100%1 / 1093
Machinery Part Replacement
Remarks
Item
12-Nozzle Head Teaching
A
ll steps above should be taken for all
sta
g
es
(
AF
,
AR
,
BF and BR
)
.
13
EJM8A-E-SMA051108-A01-00
Page 5-11-8-5
This section describes the procedures for determining the light intensity.
Tools
5-11-9 Light Intensity
Machinery Part Replacement 12-Nozzle Head Teaching
Jig
FM-0934
Light-intensity-teaching jig
None
Shadow-light-intensity-teaching jig
(Same as 8 nozzles)
Direct-light-intensity-teaching jig
(Same as 8 nozzles)
Caution
Dange
r
Warning
EJM8A-E-SMA051109-A01-00
Page 5-11-9-1
12-Nozzle Head Teaching
• Put the shadow-light-intensity-teaching
jig on the number 5 nozzle holder of the
stage to teach.
The most suitable shadow-light intensity
is calculated automatically, and saved in
the machine parameters.
4
3
Item
Press [Jig setting]
Press [Shadow light tch]
2
1
Select the desired stage.
Press [Lighting intensity].
Machinery Part Replacement
Remarks
EJM8A-E-SMA051109-A01-00
Page 5-11-9-2