Machinery Part Replacement 12-Nozzle Head Teaching • Remove the shadow-light-intensity- teaching jig from the machine. • Remove the direct-light-intensity- teaching jig from the number 5 nozzle holder of the stage to tea…

100%1 / 1093
12-Nozzle Head Teaching
• Put the shadow-light-intensity-teaching
jig on the number 5 nozzle holder of the
stage to teach.
The most suitable shadow-light intensity
is calculated automatically, and saved in
the machine parameters.
4
3
Item
Press [Jig setting]
Press [Shadow light tch]
2
1
Select the desired stage.
Press [Lighting intensity].
Machinery Part Replacement
Remarks
EJM8A-E-SMA051109-A01-00
Page 5-11-9-2
Machinery Part Replacement 12-Nozzle Head Teaching
• Remove the shadow-light-intensity-
teaching jig from the machine.
• Remove the direct-light-intensity-
teaching jig from the number 5 nozzle
holder of the stage to teach.
cRemove the shadow-light-intensity-
teaching jig from the machine.
d Put the direct-light-intensity-teaching
jig on the number 5 nozzle holder of the
stage to teach.
The most suitable direct-light intensity is
calculated automatically, and saved in
the machine parameters.
(Average: 80 to 90%)
Remarks
Press [Jig remove] and [Jig setting]
Press [Direct light tch]
Press [Jig remove].
7
6
5
Item
2
1
EJM8A-E-SMA051109-A01-00
Page 5-11-9-3
Machinery Part Replacement
This section describes the procedures for determining the nozzle exchange position.
Tools
None
Jig
Non-registered
Nozzle-changer-position-
recognition jig
Nozzle 130S
12-Nozzle Head Teaching
5-11-10       Nozzle Exchange Position
        Clean the upper surface of the changer beforehand.
Be sure to carry out this teaching after shadow mount position teaching.
12-nozzle-change-position-
teaching jig
Caution
Dange
r
Warning
EJM8A-E-SMA051110-A01-00
Page 5-11-10-1