CM602all_EJM8AESM_Service Manual - 第711页

Machinery Part Replacement Remarks Nozzle Changer (12-nozzle) Unit Item Remove the upper chute. Allen key 3 mm M4 screw 2 pcs. Remove the nozzle changer. Allen key 4 mm M5 screw 3 pcs. Iron plate Allen key 3 mm M4 x 8 mm…

100%1 / 1093
Machinery Part Replacement
Remarks
Turn off the main power.
Turn the switch to the left.
Close the MR-unit cock.
After closing the cock, turn the regulator
to the left, and release the air.
* The gauges are lined from the left as
follows: compulsory blow, bulk air and
main air.
0.49MPa to
0.54MPa
Remove the feeder cover and the chute.
Allen key 3 mm
M4 screw 4 pcs.
Remove the right side cover.
Remove the feeder cover.
Remove the tape-float-sensor cover from
the main body.
Allen key 3 mm
M4 screw 4 pcs.
Nozzle Changer (12-nozzle) Unit
4
1
Item
2
3
1
2
EJM8A-E-SMA051201-A01-00
Page 5-12-1-2
Machinery Part Replacement
Remarks
Nozzle Changer (12-nozzle) Unit
Item
Remove the upper chute.
Allen key 3 mm
M4 screw 2 pcs.
Remove the nozzle changer.
Allen key 4 mm
M5 screw 3 pcs.
Iron plate
Allen key 3 mm
M4 x 8 mm 1 pc.
Put an iron plate on the bottom of the head. (Different picture from the actual
machine, but the same procedures.)
Disconnect the nozzle-changer connector.
5
6
7
8
EJM8A-E-SMA051201-A01-00
Page 5-12-1-3
Machinery Part Replacement
Remarks
Nozzle Changer (12-nozzle) Unit
Item
Mount the nozzle changer. (Adjust the speed control.)
Allen key 5 mm
M6 screw 3 pcs.
Speed control cd
adjustment:
* Right front: 1 turn from
the fully-closed position
* Left front: 0.5 turns form
the fully-closed position
Put an dial gauge. (Different picture from the actual machine, but the
same procedures.) Dial gauge
Magnetic stand
the actual machine, but the same procedures.)
Parallelism:
Specifications: 0.02 mm
or less
Connect the nozzle-chan
g
er connector.
Position the nozzle changer so that it will be parallel. (Different picture from
9
10
11
12
Possibly interfere with
the chute.
Ex. of bad tubing
EJM8A-E-SMA051201-A01-00
Page 5-12-1-4