CM602all_EJM8AESM_Service Manual - 第732页

Optional Accessory Parts Replacement Remarks Switch off the main power. Turn the switch left. Close the cock of the MR unit. After closing the cock, turn the regulator left to remove air. * Left gauge: Forcible blow Midd…

100%1 / 1093
Optional Accessory Parts Replacement
This section describes the procedures for replacing the high-speed nozzle changer.
Tools
Phillips screwdriver #2
Short Phillips screwdriver
#2
Allen key 3 mm
Allen key 5 mm
Pipe
Nipper
Dial gauge
Magnetic stand
Iron plate
Jigs
FM-0655
Nozzle changer teaching
jig
Nozzle 120 or 130
Nozzle Changer Unit (8-nozzle type)
6-1-3     Nozzle Changer Replacement (High-Speed Machines)
Caution
Dange
r
Warning
Assembly/Adjustment
15 Min.
Teaching
5 Min.
Removal/Disassembly
15 Min.
Total
35
Part
kg
EJM8A-E-SMA060103-A01-00
Page6-1-3-1
Optional Accessory Parts Replacement
Remarks
Switch off the main power.
Turn the switch left.
Close the cock of the MR unit.
After closing the cock, turn the regulator
left to remove air.
* Left gauge: Forcible blow
Middle gauge: Bulk air
Right gauge: Main air
From 0.49MPa
to 0.54MPa
Remove the feeder cover and the chute.
Allen key 3 mm
Phillips screwdriver #2
Screw M4 2 pcs.
Screw M4 x 10mm 3 pcs.
Thick washer 3 pcs.
Remove the right side cover.
Phillips screwdriver #2
Truss screw M4 4 pcs.
Nozzle Changer Unit (8-nozzle type)
3
4
1
Item
2
1
2
EJM8A-E-SMA060103-A01-00
Page6-1-3-2
Optional Accessory Parts Replacement
Remarks
Nozzle Changer Unit (8-nozzle type)
Item
Disconnect the nozzle changer cables.
Nipper
Cable tie 150 mm
4 pcs.
J1
35= Open, J136= Closed =AF-2
AR-4
BF-B
BR-D
Remove the nozzle changer.
Allen key 4 mm
Screw M5 x 25 3 pcs.
Iron plate
Allen key 3 mm
Screw M4 x 8 mm 1 pc.
Disconnect the nozzle changer connectors.
Place the iron plate on the bottom of the head.
5
6
7
8
EJM8A-E-SMA060103-A01-00
Page6-1-3-3