Optional Accessory Parts Replacement Remarks Nozzle Changer Unit (8-nozzle type) Item Nipper Cable tie 150 mm 5 pcs. Put the side cover back on. Phillips screwdriver #2 Truss screw M4 4 pcs. Phillips screwdriver #2 Allen…

Optional Accessory Parts Replacement
Remarks
Nozzle Changer Unit (8-nozzle type)
Item
Install the nozzle changer.
Allen key 5 mm
Screw M6 x 25 3 pcs.
Thick washer 2 pcs.
Position the dial gauge.
Dial gauge
Magnetic stand
Parallelism:
Specifications:
0.02 mm or less
Connect the nozzle changer connectors.
J1■35= Open, J1■36=Closed ■=AF-2
AR-4
BF-B
BR-D
Adjust the nozzle changer to parallel.
9
10
11
12
EJM8A-E-SMA060103-A01-00
Page6-1-3-4

Optional Accessory Parts Replacement
Remarks
Nozzle Changer Unit (8-nozzle type)
Item
Nipper
Cable tie 150 mm
5 pcs.
Put the side cover back on.
Phillips screwdriver #2
Truss screw M4 4 pcs.
Phillips screwdriver #2
Allen key 3 mm
Screw M4 2 pcs.
Screw M4 x 10mm 3 pcs.
Thick washer 3 pcs.
Switch on the main power.
Turn the switch right.
Put the feeder cover and the chute back on.
Secure the cables, aligning them with other cables.
14
15
16
13
EJM8A-E-SMA060103-A01-00
Page6-1-3-5

Optional Accessory Parts Replacement
Remarks
Nozzle Changer Unit (8-nozzle type)
Item
Teaching
Nozzle Change Position See Section 4-3-9.
Teaching jig (FM-0655)
17
EJM8A-E-SMA060103-A01-00