CM602all_EJM8AESM_Service Manual - 第752页
Nozzle Changer Unit (3-nozzle type) Optional Part and Accessory Replacement Item Remark 9 Adjust the nozzle changer so that Tool/Spec./Installation it is parallel. Specifications: Parallelism: 0.02 mm or less Tool/Spec./…

Slide the shutter.
Place it on the bottom of the head
holding bracket.
Slide the shutter.
Remove the nozzle changer.
Tool/Spec./Installation
Allen key 4 mm
Screw M5 3 pcs.
6
5
Disconnect the cylinder air tube.
Tool/Spec./Installation
RemarkItem
Allen key 4 mm
Screw M5 3 pcs.
8
7
Install the nozzle changer.
Tool/Spec./Installation
Place the iron plate on the bottom of
Tool/Spec./Installation
the head.
Iron plate
Magnetic stand
Dial gauge
Screw M4
Nozzle Changer Unit (3-nozzle type)Optional Part and Accessory Replacement
EJM8A-E-SMA060203-A01-00
Page 6-2-3-3

Nozzle Changer Unit (3-nozzle type)Optional Part and Accessory Replacement
Item Remark
9
Adjust the nozzle changer so that
Tool/Spec./Installation
it is parallel.
Specifications:
Parallelism:
0.02 mm or less
Tool/Spec./Installation
Phillips screwdriver #2
Screw M4 4 pcs.
Tool/Spec./Installation
connectors.
Put the right side cover back on.
Tool/Spec./Installation
11
Connect the nozzle changer
10
Connect the cylinder air hose.
12
EJM8A-E-SMA060203-A01-00
Page 6-2-3-4

See Section 4-3-9 "Nozzle Exchange Position"
Remark
Nozzle Changer Unit (3-nozzle type)Optional Part and Accessory Replacement
13
Switch ON the main power and
Tool/Spec./Installation
air supply.
16
Teaching
Tool/Spec./Installation
See Section 4-3-9.
Phillips screwdriver #2
Allen key 3 mm
Screw M4 2 pcs.
Screw M4 3 pcs.
14
15
Put the chute and the feeder cover
back on.
Adjust the stroke of the nozzle changer shutter with the adjuster placed on
the cylinder section.
Caliper
Shutter: Open:
A=15.75±0.25 mm
B=0±0.25 mm
Shutter: Closed
A=0±0.25 mm
B=15.75±0.25 mm
Tool/Spec./Installation
Item
1
2
B
A
EJM8A-E-SMA060203-A01-00
Page 6-2-3-5