CM602all_EJM8AESM_Service Manual - 第805页

Remark Component-Thickness-Measuring Unit Option Part and Accessory Replacement Item Put the cover back on. 63 Install the cover with two "M2.6 x 4L" bolts for each: front and rear. Phillips screwdriver #1 64 P…

100%1 / 1093
Remark
Component-Thickness-Measuring Unit
Option Part and Accessory Replacement
Item
Connect CNs 39 and 40.
58
61
Secure the sensor cables with a cable tie.
Secure the sensor cables with cable ties.
60
Secure the sensor cables with cable ties.
59
Holding cable tie
Holding cable ties
Connect CNs 39 and 40.
Holding cable ties
EJM8A-E-SMA060402-A01-01
Page 6-4-2-17
Remark
Component-Thickness-Measuring Unit
Option Part and Accessory Replacement
Item
Put the cover back on.
63
Install the cover with two "M2.6 x 4L"
bolts for each: front and rear.
Phillips screwdriver #1
64
Phillips screwdriver #2
Truss screw M4 10 pcs.
Secure the sensor cables with cable ties.
62
Put the head cover and the upper cover back on.
Holding cable ties
A
lign the edges of (1) with
that of A or B, and fix the
cover.
There should be no gap
between (1) and A or B.
EJM8A-E-SMA060402-A01-01
Page 6-4-2-18
Remark
Component-Thickness-Measuring Unit
Option Part and Accessory Replacement
Item
* Since there are magnets, ensure safety
using a non-magnetic Allen keys when
working on the machine.
Bolts that come with the
cover (Large): 4 pcs.
Bolts that come with the
cover (Small): 2 pcs.
* Non-magnetic Allen key
Put the feeder cover back on.
67
Allen key 3 mm
Screw M4 4 pcs.
Turn on the power and air supply.
Remove the covers (Large) (Small) from the secondary part.
Remove the bubble wrap from the line sensor camera.
65
66
68
1
2
Bolts
(Large)
Cover (Small)
EJM8A-E-SMA060402-A01-01
Page 6-4-2-19